Control charts to evaluate long-term performance in proficiency tests

被引:0
作者
Angela Sorbo
Andrea Colabucci
Laura Ciaralli
机构
[1] European Union Reference Laboratory for Chemical Elements in Food of Animal Origin (EURL-CEFAO),Department of Food Safety and Veterinary Public Health, Istituto Superiore di Sanità
来源
Accreditation and Quality Assurance | 2013年 / 18卷
关键词
European Union Reference Laboratory; Chemical elements; Proficiency test; Shewhart control charts; Cusum control charts; Long-term performance;
D O I
暂无
中图分类号
学科分类号
摘要
As proficiency tests (PTs) provider, the European Union Reference Laboratory for Chemical Elements in Food of Animal Origin (EURL-CEFAO) yearly organizes exercises on the determination of chemical elements within the area of its mandate. The scheme is addressed to the National Reference Laboratories (NRLs) of the European Union Member States. Each PT is planned giving priority to the matrices and elements for which maximum levels are set in Commission Regulation No. 1881/2006 and following amendments as well as to those mainly considered in National Residues Control Plans. Samples to be distributed are prepared in the Laboratory’s facilities using materials purchased on the market and often adjusting the concentration levels of the analytes around their maximum levels. In the 2006–2011 period, PTs were planned as a long-term programme pursuing the general objective of providing the NRLs with a scheme that can give them the opportunity to check and improve the performance of their analytical methods and to verify the effectiveness of any corrective actions through the repetition of the same matrix. Control charts give participants the possibility of a long-term follow-up of their performance promoting the improvement of Quality Control. To this aim, Shewhart and Cusum control charts for z-scores are prepared according to ISO 13528:2005 and updated after each PT for each laboratory. z-scores are assigned using values of σpEURL-CEFAO that correspond to the level of performance appropriate to the demand. Cusum charts are also evaluated by EURL-CEFAO in order to identify problems that may cause a bias in the measurement method.
引用
收藏
页码:291 / 298
页数:7
相关论文
共 4 条
  • [1] Thompson M(2006)International harmonized protocol for the proficiency testing of analytical chemistry laboratories Pure Appl Chem 78 145-196
  • [2] Ellison SRL(2000)Recent trends in inter-laboratory precision at ppb and sub-ppb concentrations in relation to fitness for purpose criteria in proficiency testing Analyst 125 385-386
  • [3] Wood R(undefined)undefined undefined undefined undefined-undefined
  • [4] Thompson M(undefined)undefined undefined undefined undefined-undefined