Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)

被引:0
作者
Kwame Anokye Amoabeng
Anne Beate Langeland Marthinsen
Francis Hasford
Samuel Nii Adu Tagoe
Evelyn Anaafi
机构
[1] University of Ghana,Department of Medical Physics, Graduate School of Nuclear and Allied Sciences
[2] St. Olav’s University Hospital,Department of Radiotherapy
[3] Korlebu Teaching Hospital,National Centre for Radiotherapy and Nuclear Medicine
[4] Sweden – Ghana Medical Center,undefined
来源
Health and Technology | 2022年 / 12卷
关键词
VMAT; Gamma index; Quality assurance; Flattening filter free radiation; Optimization;
D O I
暂无
中图分类号
学科分类号
摘要
Volumetric Modulated Arc Therapy (VMAT) plans and its treatment are complex radiation therapy modalities and its clinical implementation requires very accurate acceptance testing and a comprehensive quality assurance program. Failure in their periodic applications can result in errors in treatment delivery. It is therefore needed to compare the calculated dose distribution to the measured dose distribution of treatment plans to ensure accuracy and efficiency to minimize errors in planned radiation dose delivery to the patient. VMAT plans for fifteen patients with cervical cancer with pathological pelvic lymph node metastasis were included in this study. Two VMAT plans were made for each patient, one using conventional 6 MV beam with flattening filter and one with flattening filter free beam (FFF). The VMAT plans were made using two arcs, and then recalculated to give the planned dose distribution to the detectors in a Delta4 phantom. All thirty VMAT plans were irradiated on the Delta4 phantom using three Elekta linear accelerators, and planned and calculated doses to the phantom were compared. Measurements were done both before and after a routine linac optimization, and variation in radiation delivery between the linacs were studied. After machine optimization, there was an increase in the mean total gamma pass rate for both the 6 MV plans from 98.7 to 99.9% and the FFF plans also had an increase in the gamma pass rate from 91.7% to 98.4% for SB5 linac. There was significant statistical difference (p < 0.05) between the pass rates of the 6 MV plans and the FFF plans. 6 MV VMAT plans with conventional flattened beams are delivered more accurately and hence more beneficial compared to flattening filter free (FFF) VMAT plans for external radiation of cervical cancer with affected pelvic lymph nodes.
引用
收藏
页码:779 / 786
页数:7
相关论文
共 50 条
  • [41] Treatment plan complexity quantification for predicting gamma passing rates in patient-specific quality assurance for stereotactic volumetric modulated arc therapy
    Xue, Xudong
    Luan, Shunyao
    Ding, Yi
    Li, Xiangbin
    Li, Dan
    Wang, Jingya
    Ma, Chi
    Jiang, Man
    Wei, Wei
    Wang, Xiao
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):
  • [42] Daily Based Quality Assurance of Volumetric Modulated Arc Therapy for the Full Session of Treatment
    Mohammad Mahfujur Rahman
    Chan Hyeong Kim
    Seonghoon Kim
    [J]. Journal of the Korean Physical Society, 2018, 73 : 990 - 1000
  • [43] Quality assurance of volumetric modulated arc therapy: Evaluation and comparison of different dosimetric systems
    Masi, L.
    Casamassima, F.
    Doro, R.
    Francescon, P.
    [J]. MEDICAL PHYSICS, 2011, 38 (02) : 612 - 621
  • [44] Physical and biological pretreatment quality assurance of the head and neck cancer plan with the volumetric modulated arc therapy
    Park, So-Hyun
    Lee, Dong-Soo
    Lee, Yun-Hee
    Lee, Seu-Ran
    Kim, Min-Ju
    Suh, Tae-Suk
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (05) : 946 - 955
  • [45] Ultrafast treatment plan optimization for volumetric modulated arc therapy (VMAT)
    Men, Chunhua
    Romeijn, H. Edwin
    Jia, Xun
    Jiang, Steve B.
    [J]. MEDICAL PHYSICS, 2010, 37 (11) : 5787 - 5791
  • [46] Volumetric modulated arc therapy (VMAT) in the treatment of esophageal cancer patients
    Stefania Martini
    Francesca Arcadipane
    Paolo Strignano
    Rosella Spadi
    Viviana Contu
    Christian Fiandra
    Riccardo Ragona
    Giorgia Catalano
    Maria Antonietta Satolli
    Michele Camandona
    Renato Romagnoli
    Umberto Ricardi
    Pierfrancesco Franco
    [J]. Medical Oncology, 2018, 35
  • [47] Effect of the Collimator Angle on Dosimetric Verification of Volumetric Modulated Arc Therapy
    Kim, Yong Ho
    Park, Ha Ryung
    Kim, Won Taek
    Kim, Dong Won
    Ki, Yongkan
    Lee, Juhye
    Bae, Jinsuk
    Park, Dahl
    Jeon, Hosang
    Nam, Ji Ho
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 243 - 247
  • [48] The determination of optimal treatment plans for Volumetric Modulated Arc Therapy (VMAT)
    Dursun, Pinar
    Taskin, Z. Caner
    Altinel, I. Kuban
    [J]. EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2019, 272 (01) : 372 - 388
  • [49] Optimal delivery of volumetric modulated arc therapy (VMAT) for moving target
    Behera, Sairam
    Daescu, Ovidiu
    Papiez, Lech
    [J]. 2011 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE WORKSHOPS, 2011, : 297 - 304
  • [50] Volumetric modulated arc therapy (VMAT) in the treatment of esophageal cancer patients
    Martini, Stefania
    Arcadipane, Francesca
    Strignano, Paolo
    Spadi, Rosella
    Contu, Viviana
    Fiandra, Christian
    Ragona, Riccardo
    Catalano, Giorgia
    Satolli, Maria Antonietta
    Camandona, Michele
    Romagnoli, Renato
    Ricardi, Umberto
    Franco, Pierfrancesco
    [J]. MEDICAL ONCOLOGY, 2018, 35 (12)