Calibration & measurement facilities for AC high current & high voltage ratio standards at NPL

被引:0
作者
S. R. Gupta
机构
[1] National Physical Laboratory,
来源
MAPAN | 2009年 / 24卷
关键词
Imaginary Component; Current Transformer; Secondary Current; High Voltage Source; Voltage Transformer;
D O I
暂无
中图分类号
学科分类号
摘要
Regular calibration of the Instrument Transformers (ITs) is very essential for the accurate measurement of power and energy at high voltages. ITs are also used in the measurement of high currents & high voltages at power frequencies. The nominal transformation of an IT depends only on the number of turns of its windings but due to various losses there are always errors in the Instrument Transformers’ ratios. The correct knowledge of their errors requires calibrations of the ITs. In this paper the methods used in calibrating the Current Transformers (CTs) & Potential Transformers (PTs) and the required accuracy have been discussed.
引用
收藏
页码:29 / 39
页数:10
相关论文
共 38 条
[31]   High Accuracy On-Line Calibration System for Current Transformers Based on Clamp-Shape Rogowski Coil and Improved Digital Integrator [J].
Zhen-hua Li ;
Su-hong Yan ;
Wei-zhong Hu ;
Zhen-xing Li ;
Yan-chun Xu .
MAPAN, 2016, 31 :119-127
[32]   High Impedance Restricted Earth Fault Relay Settings: Impact of using Auxiliary Current Transformers at Neutral End for Ratio Matching [J].
Subramanian Vanchier Payyalore ;
Sridhar Palanisamy .
Journal of The Institution of Engineers (India): Series B, 2022, 103 :469-475
[33]   High Impedance Restricted Earth Fault Relay Settings: Impact of using Auxiliary Current Transformers at Neutral End for Ratio Matching [J].
Payyalore S.V. ;
Palanisamy S. .
Journal of The Institution of Engineers (India): Series B, 2022, 103 (02) :469-475
[34]   Design and Characterization of a Low-Cost Self-Oscillating Fluxgate Transducer for Precision Measurement of High-Current [J].
Wang, Nong ;
Zhang, Zhonghua ;
Li, Zhengkun ;
He, Qing ;
Lin, Feipeng ;
Lu, Yunfeng .
IEEE SENSORS JOURNAL, 2016, 16 (09) :2971-2981
[35]   MINIMIZING THE EFFECT OF SATURATION OF HIGH-VOLTAGE CURRENT TRANSFORMERS ON THE ACCURACY OF THREE-PHASE PRIMARY MEASURING CHANNELS WITH DIGITAL OUTPUT [J].
Pankiv V. ;
Tankevych Y. ;
Tankevych S. .
Technical Electrodynamics, 2021, 2021 (06) :66-67
[36]   High-Impedance Restricted Earth Fault Relay Settings: Impact of using Auxiliary Current Transformers on Phase Side for Ratio Matching [J].
Payyalore S.V. ;
Palanisamy S. .
Journal of The Institution of Engineers (India): Series B, 2022, 103 (01) :93-99
[37]   Minimum Required Time for Reliable Measurement of Transient Fault Current as the Main Characteristic of Domestic High-Speed Protection Relays [J].
Degtyarev A.A. ;
Kuzhekov S.L. ;
Doni N.A. ;
Shurupov A.A. .
Power Technology and Engineering, 2023, 57 (03) :481-488
[38]   Online saturation detection of high-voltage current transformers of electric substation three-phase primary measuting channels in power systems transients [J].
Pankiv V.I. ;
Tankevych E.M. .
Technical Electrodynamics, 2019, 2019 (02) :63-71