Determination of optimal location of TCSC and STATCOM for congestion management in deregulated power system

被引:17
作者
Siddiqui A.S. [1 ]
Khan M.T. [1 ]
Iqbal F. [1 ]
机构
[1] Department of Electrical Engineering, Jamia Millia Islamia, New Delhi
关键词
Congestion management; Deregulation; FACTS; Sensitivity indices; STATCOM; TCSC;
D O I
10.1007/s13198-014-0332-4
中图分类号
学科分类号
摘要
In deregulated power system, congestion management is a major problem due to operational constraints. Flexible AC transmission systems (FACTS) devices can be a choice to control the power flow in congested lines. This paper explores the use of two popular FACTS devices, TCSC and STATCOM for power flow control in electrical network and their capability to decongest the network. It suggests the optimal location of TCSC and STATCOM individually to relieve congestion with minimum power losses, voltage regulation and cost of the device. The proposed method has been verified on IEEE-14 bus system for its effectiveness. Simulation work is carried out in MATLAB software. © 2015, The Society for Reliability Engineering, Quality and Operations Management (SREQOM), India and The Division of Operation and Maintenance, Lulea University of Technology, Sweden.
引用
收藏
页码:110 / 117
页数:7
相关论文
共 15 条
[1]  
Brosda J., Handschin E., Congestion management methods with special consideration of FACTS devices. Proceedings of IEEE Power Technology Conference, vol. 1, Porto, Portugal, (2001)
[2]  
Canizares, Power flow and transient stability models of FACTS controllers for voltage and angle stability studies, IEEE Power Eng Soc Winter Meet, 2, pp. 1447-1454, (2000)
[3]  
Gad M., Shinde P., Kulkarni S.U., Optimal location of TCSC by sensitivity methods, Int J Comput Eng Res, 2, 6, pp. 162-168, (2012)
[4]  
Hingorani N.G., Gyugyi L., Understanding FACTS, (2012)
[5]  
Huang G.M., Yan P., TCSC and SVC as re-dispatch tools for congestion management and TTC improvement. Proceedings of IEEE PES, Winter Meeting, vol. 1, 2002, pp. 660-665, (2002)
[6]  
Hussain S.M.S., Subbaramiah M., An analytical approach for optimal location of DSTATCOM in radial distribution system. International Conference on Energy Efficient Technologies for Sustainability (ICEETS), Nagercoil, 2013, pp. 1365-1369, (2013)
[7]  
Khan M.T., Siddiqui A.S., Congestion management in deregulated power system using FACTS device, Int J Syst Assur Eng Manag, (2014)
[8]  
Masood T., Aggarwal R.K., Qureshi S.A., Khan R.A., STATCOM model against SVC control model performance analyses technique by MATLAB. International Conference on Renewable Energies and Power Quality (ICREPQ’10), Spain, (2010)
[9]  
Musunuri S., Dehnavi G., Comparison of STATCOM, SVC, TCSC, and SSSC performance in steady state voltage stability improvement. North American Power symposium (NAPS), Arlington, 2010, pp. 1-7, (2010)
[10]  
Mwanza K., Shi Y., Tuan L.A., Economic evaluation of FACTS for congestion management in pool markets, pp. 2053-2058, (2007)