Comparison of costs in ankle fractures treated with absorbable or metallic fixation devices

被引:12
作者
Juutilainen T. [1 ,2 ]
Pätiälä H. [1 ]
Ruuskanen M. [1 ]
Rokkanen P. [1 ]
机构
[1] Department of Orthopaedics, Helsinki University Central Hospital, Helsinki
[2] FIN-02761 Espoo
关键词
Public Health; Expense; Operative Treatment; Economic Cost; Fixation Device;
D O I
10.1007/BF00393710
中图分类号
学科分类号
摘要
The economic costs of ankle fractures treated operatively with self-reinforced polyglycolide acid (SR-PGA) screws, with self-reinforced poly-L-lactide acid (SR-PLLA) screws or with metallic implants was determined. All patients were divided into three groups according to the fixation material used. Open and otherwise complicated fractures were excluded. The total expense of operations in each group was taken into account, The average total cost of an ankle fracture fixed with SR-PGA screws was £3503. In the SR-PLLA group it was £3906, and in the metallic group it was £4514. Total expenses were £1011 higher in the metallic group than in the SR-PGA group, and consequently, expenses in the metallic group were £608 higher than in the SR-PLLA group. According to this study, it seems that absorbable fixation devices are more economical than metallic implants in operative treatment of ankle fractures though as part of the differences in total expense in this series is due to the age of the patients and other dissimilarities between these groups, the results have to be interpreted carefully.
引用
收藏
页码:204 / 208
页数:4
相关论文
共 21 条
  • [1] Black J., Does corrosion matter?, J Bone Joint Surg [Br], 70, pp. 517-520, (1988)
  • [2] Bostman O.M., Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures, Clin Orthop, 278, pp. 193-199, (1992)
  • [3] Bostman O., Economic considerations on avoiding implant removals after fracture fixation by using absorbable devices, Scan J Soc Med, 22, pp. 41-45, (1994)
  • [4] Bostman O., Makela E.A., Tormala P., Rokkanen P., Transphyseal fracture fixation using biodegradable pins, J Bone Joint Surg [Br], 71, pp. 706-707, (1989)
  • [5] Bostman O., Hirvensalo E., Makinen J., Rokkanen P., Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers, J Bone Joint Surg [Br], 72, pp. 592-596, (1990)
  • [6] Bostman O., Hirvensalo E., Vainionpaa S., Vihtonen K., Tormala P., Rokkanen P., Degradable polyglycolide rods for the internal fixation of displaced bimalleolar fractures, Int Orthop, 14, pp. 1-8, (1990)
  • [7] Bostman O., Partio E., Hivensalo E., Rokkanen P., Foreign-body reactions to polyglycolide screws. Observations in 24/216 malleolar fracture cases, Acta Orthop Scand, 63, pp. 173-176, (1992)
  • [8] Buchholz R.W., Henry S., Henley M.B., Fixation with bioabsorbable screws for the treatment of fractures of the ankle, J Bone Joint Surg [Am], 7, pp. 319-324, (1994)
  • [9] Daly P.J., Fitzgerald R.H., Melton L.J., Ilstrup D.M., Epidemiology of ankle fractures in Rochester, Minnesota, Acta Orthop Scand, 58, pp. 539-544, (1987)
  • [10] Haas H.G., PDS-Splinte zur Frakturbehandlung, Handchir Mikrochir Plast Chir, 18, pp. 295-297, (1986)