Numerical Analysis of a Novel Prefabricated Concrete Beam with Double-Grouted Couplers under Static Loading

被引:0
作者
Zhiwei Lu
Bin Wu
Guoshan Xu
机构
[1] Wuhan University of Technology,School of Civil Engineering and Architecture
[2] Tokyo Institute of Technology,Dept. of Architecture and Building Engineering
[3] Sanya Science and Education Innovation Park of Wuhan University of Technology,School of Civil Engineering
[4] Harbin Institute of Technology,Key Lab of Structures Dynamic Behavior and Control, Ministry of Education
[5] Harbin Institute of Technology,Key Lab of Intelligent Disaster Mitigation
[6] Ministry of Industry and Information Technology,undefined
来源
KSCE Journal of Civil Engineering | 2023年 / 27卷
关键词
Precast concrete beam; Double-grouted couplers; Linking rebar; Finite element analysis; Parametric analysis; Rebar eccentricity;
D O I
暂无
中图分类号
学科分类号
摘要
This paper provides a nonlinear finite element (FE) investigation of a novel prefabricated beam with double-grouted coupler splices to complement the experimental work and promote its application. FE model considering the surface-to-surface contact behaviour between the prefabricated concrete and grouting mortar is constructed and validated using test data. The validated model is subsequently utilised to conduct a parametric analysis of the most influential factors comprising the diameter and eccentricity of linking rebar and connecting length. Results indicate that the fewer the grouted couplers and the shorter the coupler length, the smaller the effect on the damage pattern and stress distribution of the beam. As the tensile linking rebar diameter increases by 2 mm and 4 mm, the ultimate stress of the linking rebar decreases by 33.4% and 44.0%, respectively, and the maximal crack width in the linking region drops by 85.9% and 97.7%, respectively. Increasing the tension linking rebar diameter significantly reduces the unfavourable influence of linking rebar eccentricity on the linking zone crack width. A decrease in the filler length helps lessen the crack width in the connecting region. Based on the present study, several recommendations for practical engineering use of the developed beam are also presented.
引用
收藏
页码:3501 / 3516
页数:15
相关论文
共 191 条
[1]  
Ameli MJ(2016)Seismic analysis of precast concrete bridge columns connected with grouted splice sleeve connectors Journal of Structural Engineering 143 04016176.1-04016176.13
[2]  
Pantelides CP(2017)Computational modelling of the moment-rotation relationship for deconstructable flush end plate beam-to-column composite joints Journal of Constructional Steel Research 129 75-92
[3]  
Ataei A(2020)Experimental and numerical assessment of new precast concrete connections under bending loads Engineering Structures 212 110456-821
[4]  
Bradford MA(2017)Behavior of two new moment resisting precast beam to column connections subjected to lateral loading Engineering Structures 132 808-998
[5]  
Liu XP(2021)Bending performance analysis of precast composite beams with precast ECC plate Structures 33 986-358
[6]  
Baghdadi A(2020)Experimental study of the seismic performance of concrete beam-column frame joints with DfD connections Journal of Structural Engineering 146 04020036-58
[7]  
Heristchian M(2019)Behavior of concrete beam-column frame joints with DfD connections: A simulation study with interface modelling Engineering Structures 189 347-66
[8]  
Ledderose L(1986)Overview of PCI workshop on effective use of precast concrete for seismic resistance PCI Journal 31 48-340
[9]  
Kloft H(2018)Finite element modelling approach for precast reinforced concrete beam-to-column connections under cyclic loading Engineering Structures 174 49-634
[10]  
Bahrami S(1989)Connections between precast elements-failure outside connection region Journal of Structural Engineering 115 316-545