This study compares the effectiveness of locking and non-locking palmar plating and external fixation for unstable distal radius fractures in the elderly. In a retrospective match-paired study, 45 patients aged 50 to 70 years who underwent surgery for C1/C2 distal radius fractures were evaluated. The surgical procedures were external fixation or plating with locking or non-locking palmar plates. Radiological and functional outcomes were assessed. Outcomes according to Gartland and Werley, Martini and the Disability of the Arm, Shoulder and Hand (DASH) questionnaire were compared. The locking palmar plate fixation method demonstrated significantly better radiological and functional results in comparison to external fixation and the non-locking palmar plating methods. The subjective assessment of plate fixation proved to be better than that of external fixation. Complications and reoperations were fewer for both plate fixation groups. Our data indicates that most displaced intra-articular distal radius fractures can be treated successfully with the locking palmar plate.
引用
收藏
页码:773 / 778
页数:5
相关论文
共 95 条
[1]  
Anand A(2004)Role of dynamic external fixator in the management of fractures of distal end of radius J Indian Med Assoc 102 495-496
[2]  
Sood LK(2003)Osteosynthesis of distal radial fractures with a volar locking screw plate system Int Orthop 27 1-6
[3]  
Sud A(2004)Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient J Hand Surg [Am] 29 96-102
[4]  
Singh T(1951)Evaluation of healed Colles’ fractures J Bone Joint Surg Am 33 895-907
[5]  
Kamojia R(2003)From evidence to best practice in the management of fractures of the distal radius in adults: working towards a research agenda BMC Musculoskelet Disord 27 4-27
[6]  
Dobretz H(2002)The American academy of orthopaedic surgeons outcomes instruments: normative values from the general population J Bone Joint Surg Am 84 208-215
[7]  
Kutscha-Lissberg E(1991)External fixation for intra-articular fractures of the distal radius J Bone Joint Surg Br 73 302-306
[8]  
Fernandez DL(2005)Palmar plating system for Colles’ fractures—a preliminary report J Hand Surg [Am] 30 750-755
[9]  
Orbay JL(2005)A randomized comparison of locking and non-locking palmar plating for unstable Colles’ fractures in the elderly J Hand Surg [Br] 30 499-503
[10]  
Gartland JJ(2003)Fixation of distal radius fractures using AO titanium volar distal radius plate Hand Surg 8 7-15