Papillary Muscle Force Transducer for Measurement In Vivo

被引:0
作者
Askov J.B. [1 ,2 ]
Honge J.L. [2 ]
Nygaard H. [1 ,2 ]
Hasenkam J.M. [2 ]
Nielsen S.L. [2 ]
Jensen M.O. [1 ,2 ]
机构
[1] Department of Biomedical Engineering, Engineering College of Aarhus, Aarhus
[2] Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Skejby
关键词
Biomechanics; Device; Force; Left ventricle; Mitral valve; Papillary muscle; Strain gauge;
D O I
10.1007/s13239-011-0043-9
中图分类号
学科分类号
摘要
Force transfer from the papillary muscle tip through the chordae tendineae to the mitral valve is a crucial element of valvular-ventricular interaction and essential in maintaining proper valvular and left ventricular function; however, the complete force exchange between the papillary muscles and the mitral valve has never been assessed in vivo. The purpose of this study was to design a transducer capable of measuring the force transferred from the chordae tendineae to the papillary muscle tip with minimum interference with subvalvular geometries and papillary muscle contraction. Using computer aided design the force transducer was configured to be implanted in between the fibrous part of the papillary muscle tip and the remaining papillary muscle. The active height of the force transducer was 2 mm in order to preserve native subvalvular geometries. Strain gauges were mounted on the force transducer frame, and the force transducer was calibrated with respect to a force acting perpendicular on the plates. Furthermore, linearity, sensitivity, noise floor, and frequency response of the force transducer was tested in a dedicated setup, and the device was evaluated in an acute porcine model. Testing of the transducer confirmed it was capable of measuring the papillary muscle force in a detailed and precise fashion. In a porcine model during extracorporeal circulation, prototypes of the force transducer were implanted in the anterior and posterior papillary muscles. After weaning from cardiopulmonary bypass proper mitral valve function was verified by echocardiography and it was confirmed that the force transducer was suitable for dynamic measurements of the papillary muscle force in vivo. A force transducer capable of quantifying the force exchange between the papillary muscle and the chordae tendineae was developed and evaluated. Technical testing and animal evaluation of the force transducer confirmed that it was suitable for force measurements in an in vivo setting. © 2011 Biomedical Engineering Society.
引用
收藏
页码:196 / 202
页数:6
相关论文
共 13 条
  • [1] Dagum P., Timek T.A., Green G.R., Lai D., Daughters G.T., Liang D.H., Hayase M., Ingels Jr. N.B., Miller D.C., Coordinate-free analysis of mitral valve dynamics in normal and ischemic hearts, Circulation, 102, 19 SUPPL 3, pp. 62-69, (2000)
  • [2] Estes Jr. E.H., Dalton F.M., Entman M.L., Dixon H.B., Hackel D.B., The anatomy and blood supply of the papillary muscles of the left ventricle, Am. Heart J., 71, 3, pp. 356-362, (1966)
  • [3] Hasenkam J.M., Nygaard H., Paulsen P.K., Kim W.Y., Hansen O.K., What force can the myocardium generate on a prosthetic mitral valve ring? An animal experimental study, J. Heart Valve Dis., 3, 3, pp. 324-329, (1994)
  • [4] He S., Weston M.W., Lemmon J., Jensen M., Levine R.A., Yoganathan A.P., Geometric distribution of chordae tendineae: an important anatomic feature in mitral valve function, J. Heart Valve Dis., 9, 4, pp. 495-501, (2000)
  • [5] Jensen M.O., Fontaine A.A., Yoganathan A.P., Improved in vitro quantification of the force exerted by the papillary muscle on the left ventricular wall: three-dimensional force vector measurement system, Ann. Biomed. Eng, 29, 5, pp. 406-413, (2001)
  • [6] Jensen M.O., Jensen H., Nielsen S.L., Smerup M., Johansen P., Yoganathan A.P., Nygaard H., Hasenkam J.M., What forces act on a flat rigid mitral annuloplasty ring?, J. Heart Valve Dis., 17, 3, pp. 267-275, (2008)
  • [7] Joudinaud T.M., Kegel C.L., Flecher E.M., Weber P.A., Lansac E., Hvass U., Duran C.M., The papillary muscles as shock absorbers of the mitral valve complex. An experimental study, Eur. J. Cardiothorac. Surg., 32, 1, pp. 96-101, (2007)
  • [8] Lomholt M., Nielsen S.L., Hansen S.B., Andersen N.T., Hasenkam J.M., Differential tension between secondary and primary mitral chordae in an acute in vivo porcine model, J. Heart Valve Dis., 11, 3, pp. 337-345, (2002)
  • [9] Nichols W.W., O'Rourke M.F., The nature of flow of a fluid, In: McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles, pp. 12-53, (1990)
  • [10] Nielsen S.L., Lomholt M., Johansen P., Hansen S.B., Andersen N.T., Hasenkam J.M., Mitral ring annuloplasty relieves tension of the secondary but not primary chordae tendineae in the anterior mitral leaflet, J. Thorac. Cardiovasc. Surg., 141, 3, pp. 732-737, (2010)