Magnetic field interactions of orthodontic wires during magnetic resonance imaging (MRI) at 1.5 Tesla [Magnetische Kräfte auf kieferorthopädische Drähte während Magnetresonanztomographie bei 1,5 Tesla]

被引:24
作者
Klocke A. [1 ]
Kemper J. [2 ]
Schulze D. [2 ,3 ]
Adam G. [2 ]
Kahl-Nieke B. [1 ]
机构
[1] Department of Orthodontics, Center of Radiology, University Hospital Hamburg-Eppendorf, Hamburg
[2] Clinic of Diagnostic and Interventional Radiology, Center of Radiology, University Hospital Hamburg-Eppendorf, Hamburg
[3] Clinic of Oral and Maxillofacial Surgery, University Hospital Freiburg, Freiburg
来源
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie | 2005年 / 66卷 / 4期
关键词
Magnetic resonance imaging; Orthodontic wires; Rotational force; Safety; Translational force;
D O I
10.1007/s00056-005-0505-5
中图分类号
学科分类号
摘要
Background: Orthodontic appliances pose a potential risk during magnetic resonance imaging (MRI) due to forces on metallic objects within the static magnetic field of MRI systems. The aim of the present investigation was to measure forces on orthodontic wires caused by the static magnetic field of a 1.5-Tesla MRI system, and to assess the safety hazards associated with these forces. Materials and Methods: Thirty-two different orthodontic wires (21 arch wires, eight ligature wires and three retainer wires) were investigated in a 1.5-Tesla MRI system (Magnetom Symphony, Siemens Medical Solutions, Erlangen, Germany). The translational forces were measured using the deflection angle test (ASTM F2052-02); rotational forces were assessed on a 5-point qualitative scale. Results and Conclusion: All retainer wires and the steel arch wires (the Noninium® arch wire being the exception) were subjected to considerable rotational and translational forces within the MRI system's magnetic field. Translational forces were from 9.1- to 27.6-times as high as gravitational forces on these objects. Steel ligature wires and arch wires made of cobalt chromium, titanium molybdenum, nickel-titanium, and brass alloys showed no or negligible forces within the magnetic field. The translational and rotational forces within the MRI magnetic field should pose no risk to carefully-ligated arch wires. Steel retainer wire bonds should be checked to ensure secure attachment prior to an MRI investigation. © Urban & Vogel München.
引用
收藏
页码:279 / 287
页数:8
相关论文
共 36 条
  • [1] Designation: F2052-02. Standard test method for measurement of magnetically induced displacement force on medical devices in the magnetic resonance environment, Annual Book of ASTM Standards, 13, 1, pp. 1576-1580, (2002)
  • [2] Baker K.B., Nyenhuis J.A., Hrdlicka G., Et al., Neurostimulation systems: Assessment of magnetic field interactions associated with 1.5- and 3-Tesla MR systems, J. Magn. Reson Imaging, 21, pp. 72-77, (2005)
  • [3] Brandley W.A., Orthodontic wires, Orthodontic Materials: Scientific and Clinical Aspects, pp. 77-103, (2001)
  • [4] Carr J.J., Danger in performing MR imaging on women who have tattooed eyeliner or similar types of permanent injections, AJR Am. J. Roentgenol., 165, pp. 1546-1547, (1995)
  • [5] Chaljub G., Kramer L.A., Johnson III R.F., Et al., Projectile cylinder accidents resulting from the presence of ferromagnetic nitrous oxide or oxygen tanks in the MR suite, AJR Am. J. Roentgenol., 177, pp. 27-30, (2001)
  • [6] Chen D.W., Boy, 6, dies of skull injury during MRI: Oxygen tank becomes fatal missile in hospital, New York Times, (2001)
  • [7] Colletti P.M., Size "H" Oxygen cylinder: Accidental MR projectile at 1.5 Tesla, J. Magn. Reson Imaging, 19, pp. 141-143, (2004)
  • [8] Edwards M.B., Taylor K.M., Shellock F.G., Prosthetic heart valves: Evaluation of magnetic field interactions, heating, and artifacts at 1.5 T, J. Magn. Reson Imaging, 12, pp. 363-369, (2000)
  • [9] Greatbatch W., Miller V., Shellock F.G., Magnetic resonance safety testing of a newly-developed fiber-optic cardiac pacing lead, J. Magn. Reson Imaging, 16, pp. 97-103, (2002)
  • [10] Jackson J.G., Acker H., Permanent eyeliner and MR imaging, AJR. Am. J. Roentgenol., 149, (1987)