Comparison of extraocular and intraocular pressure transducers for measurement of transient intraocular pressure fluctuations using continuous wireless telemetry

被引:0
|
作者
Jessica V. Jasien
Ye Emma Zohner
Sonia Kuhn Asif
Lindsay A. Rhodes
Brian C. Samuels
Christopher A. Girkin
Jeffrey S. Morris
J. Crawford Downs
机构
[1] University of Alabama at Birmingham,Vision Science Graduate Program, School of Optometry
[2] Rice University,Department of Ophthalmology and Visual Sciences, School of Medicine
[3] University of Alabama at Birmingham,Perelman School of Medicine
[4] University of Pennsylvania,undefined
来源
Scientific Reports | / 10卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The optimal approach for continuous measurement of intraocular pressure (IOP), including pressure transducer location and measurement frequency, is currently unknown. This study assessed the capability of extraocular (EO) and intraocular (IO) pressure transducers, using different IOP sampling rates and duty cycles, to characterize IOP dynamics. Transient IOP fluctuations were measured and quantified in 7 eyes of 4 male rhesus macaques (NHPs) using the Konigsberg EO system (continuous at 500 Hz), 12 eyes of 8 NHPs with the Stellar EO system and 16 eyes of 12 NHPs with the Stellar IO system (both measure at 200 Hz for 15 s of every 150 s period). IOP transducers were calibrated bi-weekly via anterior chamber manometry. Linear mixed effects models assessed the differences in the hourly transient IOP impulse, and transient IOP fluctuation frequency and magnitude between systems and transducer placements (EO versus IO). All systems measured 8000–12,000 and 5000–6500 transient IOP fluctuations per hour > 0.6 mmHg, representing 8–16% and 4–8% of the total IOP energy the eye must withstand during waking and sleeping hours, respectively. Differences between sampling frequency/duty cycle and transducer placement were statistically significant (p < 0.05) but the effect sizes were small and clinically insignificant. IOP dynamics can be accurately captured by sampling IOP at 200 Hz on a 10% duty cycle using either IO or EO transducers.
引用
收藏
相关论文
共 50 条
  • [21] Intraocular pressure fluctuations in glaucoma
    Orzalesi, Nicola
    Fogagnolo, Paolo
    Rossetti, Luca
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (05) : 745 - 745
  • [22] Damping of intraocular pressure fluctuations
    Cringle, Stephen J.
    Yu, Dao-Yi
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (09): : 881 - 887
  • [23] The measurement of intraocular pressure
    Schioetz, Hj
    NATURWISSENSCHAFTEN, 1916, 4 (1-52) : 680 - 683
  • [24] Intraocular pressure measurement: Comparison of two tonometers
    Bonnet, L.
    Bellebeau, F.
    Crettet, N.
    Voute, H.
    Descotes, J.
    TOXICOLOGY LETTERS, 2005, 158 : S78 - S79
  • [25] ACTION OF SUCCINYLCHOLINE ON EXTRAOCULAR MUSCLES AND INTRAOCULAR PRESSURE
    DILLON, JB
    SABAWALA, P
    TAYLOR, DB
    GUNTER, R
    ANESTHESIOLOGY, 1957, 18 (01) : 44 - 49
  • [26] CLINICAL SIGNIFICANT EXTRAOCULAR INFLUENCES ON INTRAOCULAR PRESSURE
    MERTE, HJ
    MUNCHENER MEDIZINISCHE WOCHENSCHRIFT, 1974, 116 (42): : 1809 - 1812
  • [27] Fluctuations of the Intraocular Pressure in One Eye Influence the Intraocular Pressure in the Fellow Eye
    Voykov, Bogomil
    Blumenstock, Gunnar
    Ziemssen, Focke
    Bartz-Schmidt, Karl Ulrich
    Schultheiss, Maximillian
    CURRENT EYE RESEARCH, 2017, 42 (02) : 211 - 216
  • [28] EFFECT OF CONTINUOUS INTRAVENOUS SUCCINYLCHOLINE DRIP ON INTRAOCULAR PRESSURE AND EXTRAOCULAR MUSCLE TENSION
    BACHYRIT.P
    COLLINS, CC
    PROCEEDINGS OF THE WESTERN PHARMACOLOGY SOCIETY, 1969, 12 : 5 - &
  • [29] Electrodeposited copper inductors for intraocular pressure telemetry
    Puers, R
    Vandevoorde, G
    De Bruyker, D
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2000, 10 (02) : 124 - 129
  • [30] RADIO TELEMETRY OF INTRAOCULAR-PRESSURE INVITRO
    COOPER, RL
    BEALE, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1977, 16 (02) : 168 - 171