Comparison of extraocular and intraocular pressure transducers for measurement of transient intraocular pressure fluctuations using continuous wireless telemetry

被引:0
|
作者
Jessica V. Jasien
Ye Emma Zohner
Sonia Kuhn Asif
Lindsay A. Rhodes
Brian C. Samuels
Christopher A. Girkin
Jeffrey S. Morris
J. Crawford Downs
机构
[1] University of Alabama at Birmingham,Vision Science Graduate Program, School of Optometry
[2] Rice University,Department of Ophthalmology and Visual Sciences, School of Medicine
[3] University of Alabama at Birmingham,Perelman School of Medicine
[4] University of Pennsylvania,undefined
来源
Scientific Reports | / 10卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The optimal approach for continuous measurement of intraocular pressure (IOP), including pressure transducer location and measurement frequency, is currently unknown. This study assessed the capability of extraocular (EO) and intraocular (IO) pressure transducers, using different IOP sampling rates and duty cycles, to characterize IOP dynamics. Transient IOP fluctuations were measured and quantified in 7 eyes of 4 male rhesus macaques (NHPs) using the Konigsberg EO system (continuous at 500 Hz), 12 eyes of 8 NHPs with the Stellar EO system and 16 eyes of 12 NHPs with the Stellar IO system (both measure at 200 Hz for 15 s of every 150 s period). IOP transducers were calibrated bi-weekly via anterior chamber manometry. Linear mixed effects models assessed the differences in the hourly transient IOP impulse, and transient IOP fluctuation frequency and magnitude between systems and transducer placements (EO versus IO). All systems measured 8000–12,000 and 5000–6500 transient IOP fluctuations per hour > 0.6 mmHg, representing 8–16% and 4–8% of the total IOP energy the eye must withstand during waking and sleeping hours, respectively. Differences between sampling frequency/duty cycle and transducer placement were statistically significant (p < 0.05) but the effect sizes were small and clinically insignificant. IOP dynamics can be accurately captured by sampling IOP at 200 Hz on a 10% duty cycle using either IO or EO transducers.
引用
收藏
相关论文
共 50 条
  • [1] Comparison of extraocular and intraocular pressure transducers for measurement of transient intraocular pressure fluctuations using continuous wireless telemetry
    Jasien, Jessica, V
    Zohner, Ye Emma
    Asif, Sonia Kuhn
    Rhodes, Lindsay A.
    Samuels, Brian C.
    Girkin, Christopher A.
    Morris, Jeffrey S.
    Downs, J. Crawford
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [2] Comparison of Extraocular (EO) and Intraocular (IO) Pressure Transducers for Measurement of Transient IOP Fluctuations Using Continuous Wireless Telemetry
    Downs, J. Crawford C.
    Asif, Sonia Kuhn
    Rhodes, Lindsay Anne
    Samuels, Brian C.
    Jasien, Jessica V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [3] Continuous measurement of intraocular pressure in rabbits by telemetry
    McLaren, JW
    Brubaker, RF
    FitzSimon, JS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (06) : 966 - 975
  • [4] Cyclic Pattern of Intraocular Pressure (IOP) and Transient IOP Fluctuations in Nonhuman Primates Measured with Continuous Wireless Telemetry
    Jasien, Jessica V.
    Turner, Daniel C.
    Girkin, Christopher A.
    Downs, J. Crawford
    CURRENT EYE RESEARCH, 2019, 44 (11) : 1244 - 1252
  • [5] Intraocular Pressure and Intracranial Pressure Measurement with Continuous Wireless Telemetry to Quantify Translaminar Pressure Difference in Nonhuman Primates
    Jasien, Jessica V.
    Samuels, Brian C.
    Johnston, James M.
    Downs, J. Crawford C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [6] Continuous intraocular pressure measurement
    Hediger, A.
    Kniestedt, C.
    Zweifel, S.
    Knecht, P.
    Funk, J.
    Kanngiesser, H.
    OPHTHALMOLOGE, 2009, 106 (12): : 1111 - 1115
  • [7] Intraocular Pressure Measurement by Radio Wave Telemetry
    Todani, Amit
    Behlau, Irmgard
    Fava, Mark A.
    Cade, Fabiano
    Cherfan, Daniel G.
    Zakka, Fouad R.
    Jakobiec, Frederick A.
    Gao, Yuqing
    Dohlman, Claes H.
    Melki, Samir A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (13) : 9573 - 9580
  • [8] Effect of Anesthesia on Intraocular Pressure Measured With Continuous Wireless Telemetry in Nonhuman Primates
    Jasien, Jessica V.
    Girkin, Christopher A.
    Downs, J. Crawford
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (12) : 3830 - 3834
  • [9] Measurement of Intraocular Pressure from the Extraocular Space of the Eye using a MEMS Pressure Sensor
    Turner, Matthew
    Naber, John
    Walsh, Kevin
    2008 17TH BIENNIAL UNIVERSITY/GOVERNMENT/INDUSTRY MICRO-NANO SYMPOSIUM, PROCEEDINGS, 2008, : 217 - 219
  • [10] Using sensors to estimate intraocular pressure: a review of intraocular pressure telemetry in clinical practice
    Gillmann, Kevin
    Bravetti, Giorgio Enrico
    Niegowski, Laetitia Jessy
    Mansouri, Kaweh
    EXPERT REVIEW OF OPHTHALMOLOGY, 2019, 14 (06) : 263 - 276