Free-living core body temperature monitoring using a wrist-worn sensor after COVID-19 booster vaccination: a pilot study

被引:0
作者
Samuel Etienne
Ruben Oliveras
Giovanni Schiboni
Lukas Durrer
Fabien Rochat
Philipp Eib
Michele Zahner
Michael Osthoff
Stefano Bassetti
Jens Eckstein
机构
[1] University Hospital Basel,Division of Internal Medicine
[2] greenTEG AG,Department of Clinical Research
[3] University of Basel,Department Digitalization and ICT
[4] University Hospital Basel,undefined
来源
BioMedical Engineering OnLine | / 22卷
关键词
Remote monitoring; Wearable monitoring; Wearable sensor; Wrist-worn sensor; Free-living; Core body temperature; Fever; SARS-CoV-2; COVID-19 pandemic; Telemedicine;
D O I
暂无
中图分类号
学科分类号
摘要
Core body temperature (CBT) is a key vital sign and fever is an important indicator of disease. In the past decade, there has been growing interest for vital sign monitoring technology that may be embedded in wearable devices, and the COVID-19 pandemic has highlighted the need for remote patient monitoring systems. While wrist-worn sensors allow continuous assessment of heart rate and oxygen saturation, reliable measurement of CBT at the wrist remains challenging. In this study, CBT was measured continuously in a free-living setting using a novel technology worn at the wrist and compared to reference core body temperature measurements, i.e., CBT values acquired with an ingestible temperature-sensing pill. Fifty individuals who received the COVID-19 booster vaccination were included. The datasets of 33 individuals were used to develop the CBT prediction algorithm, and the algorithm was then validated on the datasets of 17 participants. Mean observation time was 26.4 h and CBT > 38.0 °C occurred in 66% of the participants. CBT predicted by the wrist-worn sensor showed good correlation to the reference CBT (r = 0.72). Bland–Altman statistics showed an average bias of 0.11 °C of CBT predicted by the wrist-worn device compared to reference CBT, and limits of agreement were − 0.67 to + 0.93 °C, which is comparable to the bias and limits of agreement of commonly used tympanic membrane thermometers. The small size of the components needed for this technology would allow its integration into a variety of wearable monitoring systems assessing other vital signs and at the same time allowing maximal freedom of movement to the user.
引用
收藏
相关论文
共 64 条
  • [11] Theodorsson E(2020)Accuracy of zero-heat-flux thermometry and bladder temperature measurement in critically ill patients Sci Rep 10 21746-1094
  • [12] Ström JO(2021)Assessing rectal temperature with a novel non-invasive sensor J Therm Biol 95 17-1386
  • [13] Conway A(2017)Measuring core body temperature with a non-invasive sensor J Therm Biol 66 4760-2202
  • [14] Brandes IF(2022)Evaluation of the Temple Touch Pro™ noninvasive core-temperature monitoring system in 100 adults under general anesthesia: a prospective comparison with esophageal temperature J Clin Monit Comput 22 576-416
  • [15] Bräuer A(2022)A novel non-invasive thermometer for continuous core body temperature: comparison with tympanic temperature in an acute stroke clinical setting Sensors 21 1084-1901
  • [16] Tsadok I(2019)Literature on wearable technology for connected health: scoping review of research trends, advances, and barriers J Med Internet Res 26 8-1164
  • [17] Mazgaoker S(2020)Remote patient monitoring: a systematic review Telemed J E Health 60 1384-1018
  • [18] Bräuer A(2014)Use of telemedicine technologies in the management of infectious diseases: a review Clin Infect Dis 2 1780-1413
  • [19] Ajčević M(2020)Wearable sensors for COVID-19: a call to action to harness our digital infrastructure for remote patient monitoring and virtual assessments Front Digit Health 178 2201-1228
  • [20] Loncar-Turukalo T(2021)Connected healthcare: improving patient care using digital health technologies Adv Drug Deliv Rev 384 403-1168