Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation

被引:0
作者
Young-Guk Ko
Dong-Min Kim
Jin Man Cho
So Yeon Choi
Jung Han Yoon
Jung-Sun Kim
Byeong-Keuk Kim
Donghoon Choi
Yangsoo Jang
Myeong-Ki Hong
机构
[1] Severance Cardiovascular Center,Division of Cardiology
[2] Yonsei University College of Medicine,undefined
[3] East-West Neo Medical Center,undefined
[4] Kyung Hee University College of Medicine,undefined
[5] Ajou University College of Medicine,undefined
[6] Wonju Christian Hospital,undefined
[7] Yonsei University Wonju College of Medicine,undefined
[8] Severance Biomedical Science Institute,undefined
[9] Yonsei University College of Medicine,undefined
来源
The International Journal of Cardiovascular Imaging | 2012年 / 28卷
关键词
Optical coherence tomography; Stent; Thrombosis;
D O I
暂无
中图分类号
学科分类号
摘要
Previous optical coherence tomography (OCT) studies in patients with drug-eluting stents (DESs)-related very late stent thrombosis (VLST) were scarce. Therefore, we investigated OCT findings of VLST after implantation of DESs. Using OCT, we analyzed the status of stent struts and neointimal characteristics in 18 patients who developed VLST after DES implantation. These results were compared to those in 57 patients with neointimal hyperplasia causing >40% diameter stenosis. Lipid-laden neointima was defined as a region with marked signal attenuation and a diffuse border. Four (22.2%) of 18 patients with VLST had ruptured and lipid-laden neointima inside DESs without uncovered or malapposed stent struts. In the remaining 14 patients who developed VLST without neointimal rupture, uncovered and malapposed struts were observed in nine and seven patients, respectively, and lipid-laden neointima in four patients. Lipid-laden neointima was more frequently observed in four patients with neointimal rupture than in 14 patients without neointimal rupture (100% vs. 28.6%, respectively, P = 0.023). Of 57 patients with neointimal hyperplasia, eight (14.0%) had lipid-laden neointima. Time to OCT study after DES implantation was significantly longer in the eight patients with lipid-laden neointima than in 49 patients without lipid-laden neointima (45.5 ± 17.7 months vs. 11.7 ± 7.2 months, respectively, P < 0.001). Lipid-laden neointima was detected in some patients with neointimal hyperplasia > 1 year after DES implantation. In addition to uncovered or malapposed struts, rupture of lipid-laden neointima inside DESs was identified in some patients with DES-related VLST.
引用
收藏
页码:715 / 723
页数:8
相关论文
共 301 条
[11]  
Jaeger JL(2010)Intravascular ultrasound findings in patients with very late stent thrombosis after either drug-eluting or bare-metal stent implantation J Am Coll Cardiol 55 1936-1942
[12]  
Kuntz RE(2007)Clinical end points in coronary stent trials: a case for standardized definitions Circulation 115 2344-2351
[13]  
Stone GW(2010)The initial extent of malapposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography Yonsei Med J 51 332-338
[14]  
Ellis SG(2010)Intracoronary thrombus formation after drug-eluting stents implantation: Optical coherence tomographic study Am Heart J 159 278-283
[15]  
Cox DA(2007)Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent 3 months after implantation Am J Cardiol 99 1033-1038
[16]  
Hermiller J(2008)The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography Int J Cardiol 134 180-188
[17]  
O’Shaughnessy C(2006)Assessment of coronary arterial thrombus by optical coherence tomography Am J Cardiol 97 1713-1717
[18]  
Mann JT(2011)Qualitative assessment of neointimal tissue after drug-eluting stent implantation: comparison between follow-up optical coherence tomography and intravascular ultrasound Am Heart J 161 367-372
[19]  
Turco M(2007)Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis Lancet 370 937-948
[20]  
Caputo R(2007)A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents N Engl J Med 356 989-997