Aerodynamic performance and wind-induced response of carbon fiber-reinforced polymer (CFRP) cables

被引:0
|
作者
Long, Guanxu [1 ,2 ]
Sun, Yamin [3 ]
Shang, Zhiqiang [1 ,2 ]
Wang, Xiaoyu [4 ]
Xu, Xingwei [1 ,5 ]
Wang, Tao [6 ]
机构
[1] Shandong Key Lab Highway Technol & Safety Assessme, Jinan 250000, Shandong, Peoples R China
[2] Shandong Hispeed Grp Co LTD, Innovat Res Inst, Jinan 250102, Shandong, Peoples R China
[3] Xian Univ Sci & Technol, Sch Architecture & Civil Engn, Xian 710054, Shaanxi, Peoples R China
[4] Gezhouba Grp Transportat Investment Co Ltd, Wuhan 430030, Hubei, Peoples R China
[5] Shandong Hispeed Engn Test CO LTD, Jinan 250000, Shandong, Peoples R China
[6] Changan Univ, Sch Highway, Xian 710064, Shaanxi, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
BRIDGE; SURFACE; DESIGN; OPTIMIZATION; VIBRATION; STABILITY; COST;
D O I
10.1038/s41598-024-59002-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To study the aerodynamic performance and wind-induced response of carbon fiber-reinforced polymer (CFRP) cables, CFRP cable was designed by replacing a steel cable in a tied arch bridge based on stiffness, strength and area equivalent criteria, respectively. The aerodynamic performance and wind-induced response of CFRP cable and steel cable were studied and compared by computational fluid dynamics (CFD) model. Based on the computational results, optimal cable replacement criterion was proposed for CFRP cable to replace steel cable. In addition, surface modification was conducted by engrooving vertical symmetric (VS), vertical asymmetric (VA) and helical symmetric (HS) V-shaped grooves to improve the aerodynamic performance and wind-induced response of CFRP cable. Results showed that CFRP cables exhibited inferior aerodynamic performance and wind-induced response in most cases. However, CFRP cable based on stiffness equivalent criterion exhibited better aerodynamic performance and wind-induced vibration properties compared to the other two cable replacement criteria, thus is regarded as the optimal substitute for steel cable. In addition, HS grooves generated symmetric disturbances and caused approximately equivalent boundary layer separation delays uniformly and continuously along the cable length, thus exhibiting better effect in decreasing the reverse flow region, the maximum negative flow velocity, the vortex shedding frequency and the wind-induced vibration amplitude of CFRP cable. Hence, the stiffness equivalent criterion combined with surface modification with HS V-shaped grooves was proposed to replace steel cable with CFRP cable. This study can provide insights into the aerodynamic performance and wind-induced response of CFRP cable and instructions for cable replacement practice.
引用
收藏
页数:20
相关论文
共 50 条