Aerodynamic performance and wind-induced response of carbon fiber-reinforced polymer (CFRP) cables

被引:0
|
作者
Long, Guanxu [1 ,2 ]
Sun, Yamin [3 ]
Shang, Zhiqiang [1 ,2 ]
Wang, Xiaoyu [4 ]
Xu, Xingwei [1 ,5 ]
Wang, Tao [6 ]
机构
[1] Shandong Key Lab Highway Technol & Safety Assessme, Jinan 250000, Shandong, Peoples R China
[2] Shandong Hispeed Grp Co LTD, Innovat Res Inst, Jinan 250102, Shandong, Peoples R China
[3] Xian Univ Sci & Technol, Sch Architecture & Civil Engn, Xian 710054, Shaanxi, Peoples R China
[4] Gezhouba Grp Transportat Investment Co Ltd, Wuhan 430030, Hubei, Peoples R China
[5] Shandong Hispeed Engn Test CO LTD, Jinan 250000, Shandong, Peoples R China
[6] Changan Univ, Sch Highway, Xian 710064, Shaanxi, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
BRIDGE; SURFACE; DESIGN; OPTIMIZATION; VIBRATION; STABILITY; COST;
D O I
10.1038/s41598-024-59002-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To study the aerodynamic performance and wind-induced response of carbon fiber-reinforced polymer (CFRP) cables, CFRP cable was designed by replacing a steel cable in a tied arch bridge based on stiffness, strength and area equivalent criteria, respectively. The aerodynamic performance and wind-induced response of CFRP cable and steel cable were studied and compared by computational fluid dynamics (CFD) model. Based on the computational results, optimal cable replacement criterion was proposed for CFRP cable to replace steel cable. In addition, surface modification was conducted by engrooving vertical symmetric (VS), vertical asymmetric (VA) and helical symmetric (HS) V-shaped grooves to improve the aerodynamic performance and wind-induced response of CFRP cable. Results showed that CFRP cables exhibited inferior aerodynamic performance and wind-induced response in most cases. However, CFRP cable based on stiffness equivalent criterion exhibited better aerodynamic performance and wind-induced vibration properties compared to the other two cable replacement criteria, thus is regarded as the optimal substitute for steel cable. In addition, HS grooves generated symmetric disturbances and caused approximately equivalent boundary layer separation delays uniformly and continuously along the cable length, thus exhibiting better effect in decreasing the reverse flow region, the maximum negative flow velocity, the vortex shedding frequency and the wind-induced vibration amplitude of CFRP cable. Hence, the stiffness equivalent criterion combined with surface modification with HS V-shaped grooves was proposed to replace steel cable with CFRP cable. This study can provide insights into the aerodynamic performance and wind-induced response of CFRP cable and instructions for cable replacement practice.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Improvement of Anchorage Performance of Carbon Fiber-Reinforced Polymer Cables
    Kim, Tae-Kyun
    Jung, Woo-Tai
    POLYMERS, 2022, 14 (06)
  • [2] Parameters of static response of carbon fiber reinforced polymer (CFRP) suspension cables
    Wang Li-bin
    Wu Yong
    Noori, Mohammad
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2015, 22 (08) : 3123 - 3132
  • [3] Parameters of static response of carbon fiber reinforced polymer(CFRP) suspension cables
    王立彬
    吴勇
    Mohammad Noori
    Journal of Central South University, 2015, 22 (08) : 3123 - 3132
  • [4] Parameters of static response of carbon fiber reinforced polymer (CFRP) suspension cables
    Li-bin Wang
    Yong Wu
    Mohammad Noori
    Journal of Central South University, 2015, 22 : 3123 - 3132
  • [5] Performance of carbon fiber-reinforced polymer (CFRP)-strengthened RC frame
    Shaikh Z.K.
    Sohoni V.S.
    Asian Journal of Civil Engineering, 2023, 24 (6) : 1831 - 1840
  • [6] Vehicle-Induced Response of Long-Span Suspension Bridges with Steel and Carbon Fiber-Reinforced Polymer (CFRP) Cables and Suspenders
    Sun, Yamin
    Huang, Pingming
    Mei, Kuihua
    Wang, Tao
    SCIENCE OF ADVANCED MATERIALS, 2018, 10 (06) : 913 - 922
  • [7] Performance and failure analysis of carbon fiber-reinforced polymer (CFRP) strengthened reinforced concrete (RC) beams
    Ayesha Siddika
    Krishno Saha
    Md. Sumodro Mahmud
    Sumon Chandra Roy
    Md. Abdullah Al Mamun
    Rayed Alyousef
    SN Applied Sciences, 2019, 1
  • [8] Performance and failure analysis of carbon fiber-reinforced polymer (CFRP) strengthened reinforced concrete (RC) beams
    Siddika, Ayesha
    Saha, Krishno
    Mahmud, Md Sumodro
    Roy, Sumon Chandra
    Al Mamun, Md Abdullah
    Alyousef, Rayed
    SN APPLIED SCIENCES, 2019, 1 (12):
  • [9] Advancements and Challenges in the Carbon Fiber-Reinforced Polymer (CFRP) Trimming Process
    Seo, Jaewoo
    Kim, Dong Chan
    Park, Hyunmin
    Kang, Yun Seok
    Park, Hyung Wook
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING-GREEN TECHNOLOGY, 2024, 11 (04) : 1341 - 1360
  • [10] Milling Behavior Analysis of Carbon Fiber-Reinforced Polymer (CFRP) Composites
    Ozkan, Dervis
    Gok, Mustafa Sabri
    Oge, Mecit
    Karaoglanli, Abdullah Cahit
    MATERIALS TODAY-PROCEEDINGS, 2019, 11 : 526 - 533