Non-Contact Intraocular Pressure Measurement Method using Relation between Deformed Cornea and Reflected Pneumatic Pressure

被引:0
|
作者
Hyung Jin Kim
Young Ho Seo
Byeong Hee Kim
机构
[1] Kangwon National University,Department of Mechanical and Mechatronics Engineering
来源
International Journal of Precision Engineering and Manufacturing | 2018年 / 19卷
关键词
Intraocular pressure; Corneal deformation; Focus-type hollow nozzle; Reflected pneumatic pressure; Simulation;
D O I
暂无
中图分类号
学科分类号
摘要
Deviating from existing non-contact type of intraocular pressure measurement method, which utilizes pneumatic and optical modules, this paper proposed new measurement method using pneumatic module only. In proposed method, cornea is deformed by pneumatic pressure, and pneumatic pressure reflected on cornea is measured by focus-type hollow nozzle. As a simulation results to verify proposed method, reflected pneumatic pressure decreased as the measured distance increased and the intraocular pressure increased. As an experiment results, the ratio of reflected pneumatic pressure for intraocular pressure of 10, and 50 mmHg at a measurement distance of 3 mm was about 0.21% and 0.16%, and at a measurement distance of 5 mm was about 0.21% and 0.16%, respectively. When intraocular pressure was high, low reflected pneumatic pressure was output, and simulation and experimental results showed same tendency. As a related result with the shape of the deformed cornea, cornea was largely deformed when intraocular pressure was low, and the injected pneumatic pressure was concentrated more within space formed by deformed cornea. The concentrated pneumatic pressure flowed into nozzle, and large amount of reflected pneumatic pressure was collected. The proposed method was investigated through both simulation and experimentally, and possibility was confirmed.
引用
收藏
页码:737 / 744
页数:7
相关论文
共 50 条
  • [1] Non-Contact Intraocular Pressure Measurement Method using Relation between Deformed Cornea and Reflected Pneumatic Pressure
    Kim, Hyung Jin
    Seo, Young Ho
    Kim, Byeong Hee
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2018, 19 (05) : 737 - 744
  • [2] New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle
    Kim, Hyung Jin
    Seo, Yeong Ho
    Kim, Byeong Hee
    PLOS ONE, 2017, 12 (12):
  • [3] Non-contact measurement of intraocular pressure using a modified Michelson interferometer
    Drescher, J
    Stork, W
    Hey, S
    Gundlach, A
    Glaser, KDM
    Kreiner, C
    OPHTHALMIC TECHNOLOGIES IX, PROCEEDINGS OF, 1999, 3591 : 104 - 113
  • [4] Clinical evaluation of non-contact intraocular pressure measurement method by laser interferometry
    Blanchard, S
    Dubois, P
    Zemmoury, J
    Rouland, JF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [5] Estimation of measurement uncertainty at non-contact measurement of intraocular pressure using an air impulse
    Weber, T
    Kulhanek, C
    Werthschützky, R
    SENSORS AND MEASURING SYSTEMS 2004, 2004, 1829 : 129 - 138
  • [6] On Imaging based Non-contact Tonometer for Intraocular Pressure Measurement
    Bhatt, Mahabaleswara Ram
    Rao, Shyam Vasudeva
    2013 IEEE POINT-OF-CARE HEALTHCARE TECHNOLOGIES (PHT), 2013, : 97 - 100
  • [7] The impact of silicone hydrogel contact lenses on the measurement of intraocular pressure using non-contact tonometry
    Pesic, Snezana
    Jovanovic, Svetlana
    Mitrasevic, Milos
    Vuletic, Biljana
    Jovanovic, Milena
    Jovanovic, Zorica
    VOJNOSANITETSKI PREGLED, 2017, 74 (08) : 763 - 766
  • [8] Non-contact tonometry using Corvis ST: analysis of corneal vibrations and their relation with intraocular pressure
    Boszczyk, Agnieszka
    Kasprzak, Henryk
    Siedlecki, Damian
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2019, 36 (04) : B28 - B34
  • [9] Non-contact terahertz spectroscopic measurement of the intraocular pressure through corneal hydration mapping
    Chen, Andrew
    Virk, Arjun
    Harris, Zachery
    Abazari, Azin
    Honkanen, Robert
    Arbab, M. Hassan
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (06) : 3438 - 3449
  • [10] Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients
    Vincent, Stephen J.
    Vincent, Roslyn A.
    Shields, David
    Lee, Graham A.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (04): : E163 - E170