Demonstration of Microstrip Sensor for the Feasibility Study of Non-invasive Blood-Glucose Sensing

被引:0
|
作者
Kushal Satish
Sneh Sen
机构
[1] CSIR-National Physical Laboratory,LF, HF Impedance and DC Metrology
[2] Indian Institute of Technology,Department of Textile and Fibre Engineering
[3] Indian Institute of Technology,Centre for Biomedical Engineering
来源
MAPAN | 2021年 / 36卷
关键词
Diabetes; Non-invasive blood glucose measurement; Microwave sensor; Electromagnetic properties; Sensitivity factor;
D O I
暂无
中图分类号
学科分类号
摘要
The present research work is the part of the feasibility study to implement non-invasive blood-glucose sensing using microwave-based sensor. The one-port microstrip patch antenna sensor developed to exhibit variation in its electromagnetic response with respect to blood-glucose level. It has been demonstrated through in vitro controlled experiment under laboratory conditions. The novel multi-parameter-based sensitivity factor termed as GlucoSense was also defined to evaluate the sensitivity of sensor towards the change in glucose concentration. It was established that there was a good correlation between sensor’s reflection properties and glucose concentration. The findings of the controlled experiment convincingly proved that the sensor has the potential to be effectively used for developing a suitable device for non-invasive blood-glucose sensing.
引用
收藏
页码:193 / 199
页数:6
相关论文
共 50 条
  • [41] Human body model with blood flow properties for non-invasive blood glucose measurement
    Mhatre, Pratik J.
    Joshi, Manjusha
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 72
  • [42] Non-Invasive Determination of Glucose Concentration Using a Near-Field Sensor
    Gorst, Aleksandr
    Zavyalova, Kseniya
    Mironchev, Aleksandr
    BIOSENSORS-BASEL, 2021, 11 (03):
  • [43] A Non-invasive Blood Glucose Meter Design Using Multi -Type Sensors
    Nguyen, D.
    Hienvu Nguyen
    Roveda, Janet
    MEDICAL APPLICATIONS OF RADIATION DETECTORS II, 2012, 8508
  • [44] Non-invasive monitoring of gingival crevicular fluid for estimations of blood glucose level
    Yamaguchi, M
    Kawabata, Y
    Kambe, S
    Wårdell, K
    Nystrom, FH
    Naitoh, K
    Yoshida, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (03) : 322 - 327
  • [45] Overcoming Individual Discrepancies, a Learning Model for Non-Invasive Blood Glucose Measurement
    Liu, Weijie
    Huang, Anpeng
    Wan, Ping
    APPLIED SCIENCES-BASEL, 2019, 9 (01):
  • [46] Heart Rate Variability as a Potential Non-invasive Marker of Blood Glucose Level
    Jarman L.R.
    Elliott J.L.
    Lees T.
    Clifton-Bligh R.
    Simpson A.M.
    Nassif N.
    Lal S.
    Human Physiology, 2021, 47 (2) : 209 - 218
  • [47] Non-invasive Blood Glucose Measurement Performance Analysis through UWB Imaging
    Ali, Md Shawkat
    Shoumy, N. J.
    Khatun, S.
    Kamarudin, L. M.
    Vijayasarveswari, V.
    2016 3RD INTERNATIONAL CONFERENCE ON ELECTRONIC DESIGN (ICED), 2016, : 513 - 516
  • [48] Non-invasive Blood Glucose Measurement Based on mid-Infrared Spectroscopy
    Chen, Yang
    Liu, Jiang
    Pan, Zhenni
    Shimamoto, Shirgeru
    2020 IEEE 17TH ANNUAL CONSUMER COMMUNICATIONS & NETWORKING CONFERENCE (CCNC 2020), 2020,
  • [49] Non-Invasive Blood Glucose Measurement Using Temperature-based Approach
    Kit, Stephanie Yap Hui
    Kassim, Norazan Mohd
    JURNAL TEKNOLOGI, 2013, 64 (03):
  • [50] Development of NIR Spectroscopy Based Non-invasive Blood Glucose Measuring Device
    Asekar, Megha Shyam
    Sonawane, D. N.
    2018 4TH INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2018,