共 43 条
Effects of hub-to-tip ratio and reynolds number on the performance of impulse turbine for wave energy power plant
被引:0
作者:
Ajit Thakker
Hammad Bin Khaleeq
Manabu Takao
Toshiaki Setoguchi
机构:
[1] University of Limerick,Wave Energy Research Team, Department of Mechanical and Aeronautical Engineering
[2] Sustainable Teknologies (Pvt.),Department of Engineering
[3] Ltd.,Department of Control Engineering
[4] Matsue National College of Technology,Department of Mechanical Engineering
[5] Saga University,undefined
来源:
KSME International Journal
|
2003年
/
17卷
关键词:
Fluid Machinery;
Impulse Turbine;
Reynolds Number;
Hub-to-Tip Ratio;
Wave Power Conversion;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
The objective of this paper is to present the performance comparison of the impulse turbines for different diameters. In the study, the investigation has been performed experimentally by model testing for some diameters, especially 0.3 m and 0.6 m. The experiment was performed for Reynolds number range of 0.17 X 105—1.09X 105 and for different values of hub-to-tip ratiov ranging from 0.6 to 0.85. As a result, it was found that the critical Reynolds number is to be around 0.5 X 105 for v=0.6 and 0.4X 105 for v=0.7. For the hub-to-tip ratio, the optimum value is 0.7 when the turbine is operated at lower Reynolds number. However, its value seems to be 0.6 at higher Reynolds number in the tested range.
引用
收藏
页码:1767 / 1774
页数:7
相关论文