Intercentre Reproducibility of Magnetic Resonance T2* Measurements of Myocardial Iron in Thalassaemia

被引:0
作者
Mark A. Westwood
David N. Firmin
Matta Gildo
Galanello Renzo
Gotsis Stathis
Karagiorga Markissia
Berdoukas Vasili
Dudley J. Pennell
机构
[1] Royal Brompton Hospital,CMR Unit
[2] Hospital Brotzu,Department of Radiology
[3] Department of Thalassemia and other Hematologic Diseases,Department of Magnetic Resonance
[4] Institute EUROMEDICA-ENCEPHALOS,Department of Haematology
[5] Agia Sophia Childrens hospital,undefined
来源
The International Journal of Cardiovascular Imaging | 2005年 / 21卷
关键词
anemia; cardiomyopathy; heart failure; magnetic resonance imaging; reproducibility; thalassemia;
D O I
暂无
中图分类号
学科分类号
摘要
In transfusion-dependent thalassemia major, iron-induced cardiomyopathy is the predominant cause of morbidity and mortality. Assessment of myocardial iron loading using MRI gradient echo T2* measurements have been described, but has only been performed at one centre in London. We assessed the transferability of this method by comparing the results from three different MR scanners in three different countries. Ten patients with thalassemia major underwent myocardial T2* assessment using a Siemens Sonata Scanner in London. Patients were also scanned with either a similar T2* sequence on a GE Systems CVI scanner in Athens, or a GE Systems signa echospeed scanner in Cagliari. Two scans were performed at the respective site in all patients to assess interstudy reproducibility at each site. The mean difference and coefficient of variability for the heart between scanners was 0.08 ms and 9.7% between London and Athens; and 0.30 ms and 1.6% between London and Cagliari. The interstudy mean difference and coefficient of variability for the heart in Athens was 0.6 ms and 3.5%, and 0.2 ms and 2.4% in Cagliari. In conclusion, the myocardial iron estimations were consistent between the three centres with scanners of differing manufacture, suggesting that this technique may have widespread application in the assessment of patients with iron overload conditions such as thalassaemia.
引用
收藏
页码:531 / 538
页数:7
相关论文
共 50 条
[31]   Multicenter validation of the magnetic resonance T2* technique for quantification of pancreatic iron [J].
Antonella Meloni ;
Daniele De Marchi ;
Laura Pistoia ;
Emanuele Grassedonio ;
Giuseppe Peritore ;
Paolo Preziosi ;
Gennaro Restaino ;
Riccardo Righi ;
Ada Riva ;
Stefania Renne ;
Nicolò Schicchi ;
Antonino Vallone ;
Angelo Peluso ;
Calogera Gerardi ;
Vincenzo Positano ;
Alessia Pepe .
European Radiology, 2019, 29 :2246-2252
[32]   Peripheral nerve MRI: precision and reproducibility of T2*-derived measurements at 3.0-T [J].
Tagliafico, Alberto ;
Bignotti, Bianca ;
Tagliafico, Giulio ;
Martinoli, Carlo .
SKELETAL RADIOLOGY, 2015, 44 (05) :679-686
[33]   Myocardial iron overload assessment by T2*magnetic resonance imaging in adult transfusion dependent patients with acquired anemias [J].
Di Tucci, Anna Angela ;
Matta, Gildo ;
Deplano, Simona ;
Gabbas, Attilio ;
Depau, Cristina ;
Derudas, Daniele ;
Caocci, Giovanni ;
Agus, Annalisa ;
Angelucci, Emanuele .
HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2008, 93 (09) :1385-1388
[34]   Cardiovascular magnetic resonance T2 mapping can detect myocardial edema in idiopathic dilated cardiomyopathy [J].
Nishii, Tatsuya ;
Kono, Atsushi K. ;
Shigeru, Mayumi ;
Takamine, Sachiko ;
Fujiwara, Sei ;
Kyotani, Katsusuke ;
Aoyama, Nobukazu ;
Sugimura, Kazuro .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 :65-72
[35]   Cardiovascular magnetic resonance T2 mapping can detect myocardial edema in idiopathic dilated cardiomyopathy [J].
Tatsuya Nishii ;
Atsushi K. Kono ;
Mayumi Shigeru ;
Sachiko Takamine ;
Sei Fujiwara ;
Katsusuke Kyotani ;
Nobukazu Aoyama ;
Kazuro Sugimura .
The International Journal of Cardiovascular Imaging, 2014, 30 :65-72
[36]   Multi-center validation of the transferability of the magnetic resonance T2*technique for the quantification of tissue iron [J].
Tanner, Mark A. ;
He, Taigang ;
Westwood, Mark A. ;
Firmin, David N. ;
Pennell, Dudley J. ;
Piga, Antonio ;
de Berardinis, Armando ;
Cohen, Alan ;
Fogel, Mark ;
Hadjigavriel, Michael ;
Sitarou, Maria ;
Kolnakou, Annita ;
Pavlou, Maria ;
Diamantis, Homer ;
Christou, Sotiroula ;
Pangalou, Evdokia ;
Simamonian, Krikor ;
Eracleous, Eleni ;
Ecomomides, Charalambos ;
Galanello, Renzo ;
Matta, Gildo ;
Forni, Gianluca ;
Lamagna, Martina ;
Scettro, Marco ;
Englezos, Panos ;
Eleftheriou, Androulla .
HAEMATOLOGICA, 2006, 91 (10) :1388-1391
[37]   Reproducibility of in vivo magnetic resonance imaging T1rho and T2 relaxation time measurements of hip cartilage at 3.0T in healthy volunteers [J].
Nemeth, Angeline ;
Di Marco, Lucy ;
Boutitie, Florent ;
Sdika, Michael ;
Grenier, Denis ;
Rabilloud, Muriel ;
Beuf, Olivier ;
Pialat, Jean-Baptiste .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (04) :1022-1033
[38]   Magnetic susceptibility derived from T2 and T2*-weighted magnetic resonance magnitude images [J].
Vegh, Viktor ;
Kording, Fabian ;
Venkatachalam, Taracad K. ;
Reutens, David C. .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2012, 41B (01) :28-36
[39]   An online open-source tool for automated quantification of liver and myocardial iron concentrations by T2*magnetic resonance imaging [J].
Git, K-A ;
Fioravante, L. A. B. ;
Fernandes, J. L. .
BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1053)
[40]   Cleaved Iron Oxide Nanoparticles as T2 Contrast Agents for Magnetic Resonance Imaging [J].
Jeon, Sung Lan ;
Chae, Min Kyung ;
Jang, Eun Ju ;
Lee, Chulhyun .
CHEMISTRY-A EUROPEAN JOURNAL, 2013, 19 (13) :4217-4222