Two -fluid nonlinear mathematical model for pulsatile blood flow through catheterized arteries

被引:0
作者
D. S. Sankar
Usik Lee
机构
[1] Inha University,Department of Mechanical Engineering
[2] University Science Malaysia,School of Mathematical Sciences
来源
Journal of Mechanical Science and Technology | 2009年 / 23卷
关键词
Two-fluid model; Herschel-bulkley fluid; Newtonian fluid; Pulsatile flow; Catheterized artery; Longitudinal impedance;
D O I
暂无
中图分类号
学科分类号
摘要
The pulsatile flow of blood through a catheterized artery is analyzed, assuming the blood as a two-fluid model with the suspension of all the erythrocytes in the core region as a Herschel-Bulkley fluid and the peripheral region of plasma as a Newtonian fluid. The resulting system of the nonlinear implicit system of partial differential equations is solved by perturbation method. The expressions for shear stress, velocity, flow rate, wall shear stress and longitudinal impedance are obtained. The variations of these flow quantities with yield stress, catheter radius ratio, amplitude, pulsatile Reynolds number ratio and peripheral layer thickness are discussed. The velocity and flow rate are observed to decrease, and the wall shear stress and resistance to flow increase when the yield stress increases. The plug flow velocity and flow rate decrease, and the longitudinal impedance increases when the catheter radius ratio increases. The velocity and flow rate increase while the wall shear stress and longitudinal impedance decrease with the increase of the peripheral layer thickness. The estimates of the increase in the longitudinal impedance are significantly lower for the present two-fluid model than those of the single-fluid model.
引用
收藏
页码:1650 / 1669
页数:19
相关论文
共 50 条
  • [31] ANALYSIS OF PULSATILE BLOOD FLOW IN AXIALLY MOVING ARTERIES
    Yao Da-kang
    Journal of Hydrodynamics(SerB)., 2000, (03) : 93 - 102
  • [32] A viscoelastic fluid-structure interaction model for carotid arteries under pulsatile flow
    Wang, Zhongjie
    Wood, Nigel B.
    Xu, Xiao Yun
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2015, 31 (05)
  • [33] Influence of Heat and Mass Transfer on Newtonian Biomagnetic Fluid of Blood Flow Through a Tapered Porous Arteries with a Stenosis
    Nadeem, S.
    Akbar, Noreen Sher
    Hayat, T.
    Hendi, Awatif A.
    TRANSPORT IN POROUS MEDIA, 2012, 91 (01) : 81 - 100
  • [34] Numerical and Analytical Study of Two-Layered Unsteady Blood Flow through Catheterized Artery
    Zaman, Akbar
    Ali, Nasir
    Sajid, M.
    Hayat, Tasawar
    PLOS ONE, 2016, 11 (08):
  • [35] Computational Fluid Dynamics Analysis of Blood Flow through Stented Arteries
    Mohammad, Shafiullah
    Majumdar, Pradip
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 3A, 2014,
  • [36] Mathematical analysis of Phan-Thien-Tanner fluid model for blood in arteries
    Akbar, Noreen Sher
    Nadeem, S.
    INTERNATIONAL JOURNAL OF BIOMATHEMATICS, 2015, 8 (05)
  • [37] Pulsatile flow of a shear-thinning model for blood through a two-dimensional stenosed channel
    Nandakumar, N.
    Sahu, Kirti Chandra
    Anand, M.
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2015, 49 : 29 - 35
  • [38] Mathematical Analysis of Casson Fluid Model for Blood Rheology in Stenosed Narrow Arteries
    Venkatesan, J.
    Sankar, D. S.
    Hemalatha, K.
    Yatim, Yazariah
    JOURNAL OF APPLIED MATHEMATICS, 2013,
  • [39] Blood flow suspension in tapered stenosed arteries for Walter's B fluid model
    Akbar, Noreen Sher
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2016, 132 : 45 - 55
  • [40] Particulate suspension blood flow through a narrow catheterized artery
    Srivastava, V. P.
    Srivastava, Rashmi
    COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2009, 58 (02) : 227 - 238