Design of Two-Dimensional Photonic Crystal-based Biosensor for Abnormal Tissue Analysis

被引:0
作者
A. Asuvaran
G. Elatharasan
机构
[1] University College of Engineering,Department of Electronics and Communication Engineering
[2] University College of Engineering,Department of Mechanical Engineering
来源
Silicon | 2022年 / 14卷
关键词
Minimally invasive surgery; Photonic crystal; Bio-sensor; Refractive index;
D O I
暂无
中图分类号
学科分类号
摘要
The identification and subsequent classification of different brain tissues is critical for detecting abnormalities during robot-assisted minimally invasive surgery that includes connection with the tissues. In this work, an optical sensor was designed to assess the refractive index (RI) of different brain tissues while the robotic surgery is performed. The proposed design is based on a two-dimensional photonic crystal biosensor powered by electromagnetic radiation. It operates within the wavelength range from 1648nm to 1794nm intended to effectively detect the changes in the RI of different tissues. Because the RI of abnormal tissues is significantly different from that of normal tissues, the sensor is capable of distinguishing tumors and cancer-infected brain tissues from normal brain tissues. The sensor exhibits different ranges of frequency, wavelength, and amplitude spectra, which respond to small changes that occur in the RI of the brain tissue. The simulation results showed that the photonic crystal biosensor has a high sensitivity of 4615.38nm/RIU, quality factor of 573, and detection limit of 0.0013 RIU.
引用
收藏
页码:7203 / 7210
页数:7
相关论文
共 131 条
[1]  
Udaka YT(2018)Pediatric brain tumors Neurol Clin 36 533-556
[2]  
Packer RJ(2015)"Anisotropic patterning to reduce instability of concentric-tube robots" IEEE Trans Robot 31 1311-1323
[3]  
Lee DY(2019)Continuously variable stiffness mechanism using non uniform patterns on coaxial tubes for continuum microsurgical robot IEEE Trans Robot 4 1202-1207
[4]  
Kim J(2019)Cable-less, magnetically driven forceps for minimally invasive surgery IEEE Robot Autom Lett 10 251-256
[5]  
Kim JS(2014)Forces exerted during micro neurosurgery: a cadaver study IntJ Med Robot 15 937-950
[6]  
Baek C(2016)Pursuing prosthetic electronic skin Nat Mater 63 6184-6193
[7]  
Noh G(2016)Milling state identification based on vibration sense of a robotic surgical system IEEE Trans Ind Electron 65 9593-9603
[8]  
Kim DN(2018)Contact force control on soft membrane for an ear surgical device IEEE Trans Ind Electron 16 1294-1303
[9]  
Kim J(2021)A novel 3-DOF force sensing micro needle with integrated fiber bragg grating for microsurgery IEEE Trans Ind Electron 31 1214-1224
[10]  
Choi W-Y(2021)Implantable Fiber Bragg Grating sensor for continuous heart activity monitoring: ex-vivo and in-vivo validation IEEE Sensors J 65 2755-2765