Resolution analysis of thermal neutron radiography based on accelerator-driven compact neutron source

被引:0
作者
Lian-Xin Zhang
Si-Ze Chen
Zao-Di Zhang
Tao-Sheng Li
Chuan Peng
Lei Ren
Rui Zhang
Dan Xiao
Yong Zhang
机构
[1] Chinese Academy of Sciences,Hefei Institutes of Physical Science
[2] University of Science and Technology of China,undefined
来源
Nuclear Science and Techniques | 2023年 / 34卷
关键词
Neutron radiography; Spatial resolution; Accelerator-driven neutron source; Geant4; MTF; ESF;
D O I
暂无
中图分类号
学科分类号
摘要
Owing to the immobility of traditional reactors and spallation neutron sources, the demand for compact thermal neutron radiography (CTNR) based on accelerator neutron sources has rapidly increased in industrial applications. Recently, thermal neutron radiography experiments based on a D-T neutron generator performed by Hefei Institutes of Physical Science indicated a significant resolution deviation between the experimental results and the values calculated using the traditional resolution model. The experimental result was up to 23% lower than the calculated result, which hinders the achievement of the design goal of a compact neutron radiography system. A GEANT4 Monte Carlo code was developed to simulate the CTNR process, aiming to identify the key factors leading to resolution deviation. The effects of a low collimation ratio and high-energy neutrons were analyzed based on the neutron beam environment of the CTNR system. The results showed that the deviation was primarily caused by geometric distortion at low collimation ratios and radiation noise induced by high-energy neutrons. Additionally, the theoretical model was modified by considering the imaging position and radiation noise factors. The modified theoretical model was in good agreement with the experimental results, and the maximum deviation was reduced to 4.22%. This can be useful for the high-precision design of CTNR systems.
引用
收藏
相关论文
共 79 条
[1]  
Johnson MW(1995)The industrial uses of neutrons Appl. Radiat. Isot. 46 673-680
[2]  
Cheng YP(2022)Imaging internal density structure of the Laoheishan volcanic cone with cosmic ray muon radiography Nucl. Sci. Tech. 33 88-616
[3]  
Han R(2004)Neutron radiography and other NDE tests of main rotor helicopter blades Appl. Radiat. Isotopes. 61 609-366
[4]  
Li ZW(2018)The use of electron linac for high quality thermal neutron radiography unit Nucl. Instrum. Meth. A. 908 361-30
[5]  
De Beer FC(2012)Neutron radiography handbook: nuclear science and technology Springer Sci. Bus. Med. 21 1-78
[6]  
Coetzer M(2012)Neutron radiography with compact accelerator at Peking University: problems and solutions Physcs. Proc. 26 70-327
[7]  
Fendeis D(2000)Prediction and measurement of neutron energy spectrum in a material test research reactor Ann. Nucl. Energy. 27 311-91
[8]  
Fantidis JG(2015)Neutron radiography facility at IBR-2 high flux pulsed reactor: first results Physcs. Proc. 69 87-3911
[9]  
Hardt P(2020)New neutron radiography and tomography facility TITAN at the WWR-K reactor Nucl. Instrum. Meth. A. 982 164572-9
[10]  
Röttger H(2006)Design and performance of a thermal neutron imaging facility at the North Carolina State University PULSTAR reactor IEEE Trans. Nucl. Sci. 53 3904-85