Development of a new water sterilization device with a 365 nm UV-LED

被引:0
作者
Mirei Mori
Akiko Hamamoto
Akira Takahashi
Masayuki Nakano
Noriko Wakikawa
Satoko Tachibana
Toshitaka Ikehara
Yutaka Nakaya
Masatake Akutagawa
Yohsuke Kinouchi
机构
[1] The University of Tokushima,Department of Electrical and Electronic Engineering, Institute of Socio Techno Sciences
[2] The University of Tokushima Graduate School,Department of Nutrition and Metabolism, Institute of Health Biosciences
[3] The University of Tokushima Graduate School,Department of Physiology, Institute of Health Biosciences
来源
Medical & Biological Engineering & Computing | 2007年 / 45卷
关键词
UVA-LED; Disinfection; Sterilization; Bacteria;
D O I
暂无
中图分类号
学科分类号
摘要
Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5α, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device
引用
收藏
页码:1237 / 1241
页数:4
相关论文
共 43 条
  • [1] Chang HCJ(1985)UV inactivation of pathogenic and indicator Microorganisms 49 1361-1365
  • [2] Ossoff SF(2006)UV excimer lamp irradiation of fiboblasts: the influence on antioxidant homeostasis IEEE Trans Plasma Sci 34 1359-1364
  • [3] Lobe DC(1995)Development of toxic degradation products during heat sterilization of glucose-containing fluids for peritoneal dialysis: influence of time and temperature Perit Dial Int 15 26-32
  • [4] Dorfman MH(2004)The preparation of TiO2 nanometer photocatalyst film by a hydrothermal method and its sterilization performance for Giardia lamblia Water Res 38 713-719
  • [5] Dumais CM(1987)Comparative assessment of chlorine, heat, ozone, and UV light for killing Appl Environ Microbiol 53 447-453
  • [6] Qualls RG(1997) within a model plumbing system Water Environ Res 69 14-24
  • [7] Johnson JD(2004)Testing the equivalency of ultraviolet light and chlorine for disinfection of wastewater to reclamation standards Water Res 38 2757-2763
  • [8] Erofeev MV(1985)Photoreactivation of Appl Environ Microbiol 49 1-7
  • [9] Kieft IE(1982) after binactivation by low or medium-pressure ultraviolet lamp Appl Environ Microbiol 44 972-987
  • [10] Sosnin EA(2006)A new medium for the enumeration and subculture of bacteria from potable water IEEE Trans Prasma Sci 34 1365-1369