Treatment of lung tumours with high-energy microwave ablation: a single-centre experience

被引:19
作者
Ierardi, Anna Maria [1 ]
Coppola, Andrea [1 ]
Lucchina, Natalie [1 ]
Carrafiello, Gianpaolo [2 ]
机构
[1] Insubria Univ, Dept Radiol, Intervent Radiol, Viale Borri 57, I-21100 Varese, VA, Italy
[2] Univ Milan, San Paolo Hosp, Dept Hlth Sci Diagnost & Intervent Radiol, Via A di Rudini 8, I-20142 Milan, Italy
关键词
High-energy microwave ablation (MWA); Cone-beam CT (CBCT); Efficacy; Safety; RADIOFREQUENCY ABLATION; RESPONSE EVALUATION; THERMAL ABLATION; PORCINE MODEL; CT FINDINGS; MALIGNANCIES; METASTASES; GUIDELINES; THERAPY; CANCER;
D O I
10.1007/s12032-016-0861-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of our study is to report safety, technical success, effectiveness, local progression-free survival (LPFS) and overall survival of percutaneous microwave ablation (MWA) to treat lung tumours unsuitable for surgery. Nineteen patients with thirty-one tumours (mean diameter 2.4 cm) underwent percutaneous MWA in 28 sessions. Microwave ablation was carried out using a 2450-MHz generator (Emprint/Covidien, Boulder, CO, USA). Procedures were performed under cone-beam CT (CBCT) and under fluoro-CT (one session) guidance. Safety, technical success, effectiveness, LPFS and overall survival (OS) were evaluated. Safety was defined as the frequency of major and minor complications. The efficacy was evaluated on the basis of imaging characteristics, using RECIST criteria. CT follow-up was performed at 1, 3 and 6 months and yearly. LPFS was defined as the interval between MWA treatment and evidence of local recurrence, if there was any. OS was defined as the percentage of patients who were still alive. We registered one major complication (purulent hydro-pneumothorax). Minor complications were spontaneously resolved (pneumothorax and perilesional haemorrhagic effusion). Technical success was 100%. Residual disease was registered in two cases, one of whom was retreated. Complete ablation was obtained in the remaining cases (90.3%). During available follow-up (mean 9.6 months), 9/31 tumours demonstrated local recurrence. Five tumours were retreated, and none of them presented residual disease during follow-up (LPFS 22.6%). Overall survival was 93.8%. Percutaneous high-energy MWA is a safe, effective and confident technique to treat lung tumours not suitable for surgery.
引用
收藏
页数:7
相关论文
共 28 条
  • [1] Microwave tissue ablation: Biophysics, technology, and applications
    Brace C.L.
    [J]. Critical Reviews in Biomedical Engineering, 2010, 38 (01) : 65 - 78
  • [2] Pulmonary Thermal Ablation: Comparison of Radiofrequency and Microwave Devices by Using Gross Pathologic and CT Findings in a Swine Model
    Brace, Christopher L.
    Hinshaw, J. Louis
    Laeseke, Paul F.
    Sampson, Lisa A.
    Lee, Fred T., Jr.
    [J]. RADIOLOGY, 2009, 251 (03) : 705 - 711
  • [3] Post-radiofrequency ablation syndrome after percutaneous radiofrequency of abdominal tumours: One centre experience and review of published works
    Carrafiello, G.
    Lagana, D.
    Lanniello, A.
    Dionigi, G.
    Novario, R.
    Recaldini, C.
    Mangini, M.
    Cuffari, S.
    Fugazzola, C.
    [J]. AUSTRALASIAN RADIOLOGY, 2007, 51 (06): : 550 - 554
  • [4] Microwave ablation of lung tumours: single-centre preliminary experience
    Carrafiello, Gianpaolo
    Mangini, Monica
    Fontana, Federico
    Ierardi, Anna Maria
    De Marchi, Giuseppe
    Rotolo, Nicola
    Chini, Claudio
    Cuffari, Salvatore
    Fugazzola, Carlo
    [J]. RADIOLOGIA MEDICA, 2014, 119 (01): : 75 - 82
  • [5] Carrafiello Gianpaolo, 2008, Int J Surg, V6 Suppl 1, pS65, DOI 10.1016/j.ijsu.2008.12.028
  • [6] Midterm local efficacy and survival after radiofrequency ablation of lung tumors with minimum follow-up of 1 year:: Prospective evaluation
    de Baere, Thierry
    Palussiere, Jean
    Auperin, Anne
    Hakime, Antoine
    Abdel-Rehim, Mohamed
    Kind, Michele
    Dromain, Clarisse
    Ravaud, Alain
    Tebboune, Nathalie
    Boige, Valerie
    Malka, David
    Lafont, Clarisse
    Ducreux, Michel
    [J]. RADIOLOGY, 2006, 240 (02) : 587 - 596
  • [7] Microwave ablation with triaxial antennas tuned for lung: Results in an in vivo porcine model
    Durick, Nathan A.
    Laeseke, Paul F.
    Broderick, Lynn S.
    Lee, Fred T., Jr.
    Sampson, Lisa A.
    Frey, Tina M.
    Warner, Thomas F.
    Fine, Jason P.
    Van der Weide, Daniel W.
    Brace, Christopher L.
    [J]. RADIOLOGY, 2008, 247 (01) : 80 - 87
  • [8] Percutaneous High-Energy Microwave Ablation for the Treatment of Pulmonary Tumors: A Retrospective Single-Center Experience
    Egashira, Yoshiaki
    Singh, Saurabh
    Bandula, Steve
    Illing, Rowland
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (04) : 474 - 479
  • [9] Feng Weijian, 2002, Zhonghua Zhongliu Zazhi, V24, P388
  • [10] Thoracoscopic Lobectomy for Non-small Cell Lung Cancer
    Gaudet, Matthew A.
    D'Amico, Thomas A.
    [J]. SURGICAL ONCOLOGY CLINICS OF NORTH AMERICA, 2016, 25 (03) : 503 - +