Targeted analysis of glycomics liquid chromatography/mass spectrometry data

被引:0
|
作者
Jonathan M. Dreyfuss
Christopher Jacobs
Yevgeniy Gindin
Gary Benson
Gregory O. Staples
Joseph Zaia
机构
[1] Boston University,Graduate Program in Bioinformatics
[2] National Institutes of Health,Genetics Branch, National Cancer Institute
[3] Boston University,Center for Biomedical Mass Spectrometry, Department of Biochemistry
[4] Agilent Laboratories,undefined
[5] Boston University Medical Campus,undefined
来源
Analytical and Bioanalytical Chemistry | 2011年 / 399卷
关键词
Glycomics; Glycosaminoglycan; Heparan sulfate; Mass spectrometry; Bioinformatics; Proteoglycan;
D O I
暂无
中图分类号
学科分类号
摘要
Hydrophilic interaction chromatography (HILIC) liquid chromatography/mass spectrometry (LC/MS) is appropriate for all native and reductively aminated glycan classes. HILIC carries the advantage that retention times vary predictably according to oligosaccharide composition. Chromatographic conditions are compatible with sensitive and reproducible glycomics analysis of large numbers of samples. The data are extremely useful for quantitative profiling of glycans expressed in biological tissues. With these analytical developments, the rate-limiting factor for widespread use of HILIC LC/MS in glycomics is the analysis of the data. In order to eliminate this problem, a Java-based open source software tool, Manatee, was developed for targeted analysis of HILIC LC/MS glycan datasets. This tool uses user-defined lists of compositions that specify the glycan chemical space in a given biological context. The program accepts high-resolution LC/MS data using the public mzXML format and is capable of processing a large data file in a few minutes on a standard desktop computer. The program allows mining of HILIC LC/MS data with an output compatible with multivariate statistical analysis. It is envisaged that the Manatee tool will complement more computationally intensive LC/MS processing tools based on deconvolution and deisotoping of LC/MS data. The capabilities of the tool were demonstrated using a set of HILIC LC/MS data on organ-specific heparan sulfates.
引用
收藏
页码:727 / 735
页数:8
相关论文
共 50 条
  • [1] Targeted analysis of glycomics liquid chromatography/mass spectrometry data
    Dreyfuss, Jonathan M.
    Jacobs, Christopher
    Gindin, Yevgeniy
    Benson, Gary
    Staples, Gregory O.
    Zaia, Joseph
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (02) : 727 - 735
  • [2] Clinical Glycomics Employing Graphitized Carbon Liquid Chromatography–Mass Spectrometry
    Kathrin Stavenhagen
    Daniel Kolarich
    Manfred Wuhrer
    Chromatographia, 2015, 78 : 307 - 320
  • [3] Clinical Glycomics Employing Graphitized Carbon Liquid Chromatography-Mass Spectrometry
    Stavenhagen, Kathrin
    Kolarich, Daniel
    Wuhrer, Manfred
    CHROMATOGRAPHIA, 2015, 78 (5-6) : 307 - 320
  • [4] Future potential of targeted component analysis by multidimensional liquid chromatography mass spectrometry
    Regnier, F
    Huang, G
    JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) : 3 - 10
  • [5] Analysis of cannabinoids by liquid chromatography— Thermospray mass spectrometry and liquid chromatography— Tandem mass spectrometry
    K. Ndjoko
    J. -L. Wolfender
    K. Hostettmann
    Chromatographia, 1998, 47 : 72 - 76
  • [6] Analysis of cannabinoids by liquid chromatography - Thermospray mass spectrometry and liquid chromatography - Tandem mass spectrometry
    Ndjoko, K
    Wolfender, JL
    Hostettmann, K
    CHROMATOGRAPHIA, 1998, 47 (1-2) : 72 - 76
  • [7] A Toolkit for Interactive and Batch Analysis of Glycomics and Glycoproteomics Mass Spectrometry Data
    Klein, Joshua A.
    Khatri, Kshitij
    Carvalho, Luis
    Zaia, Joseph
    GLYCOBIOLOGY, 2016, 26 (12) : 1458 - 1458
  • [8] Analysis of brassinosteroids by liquid chromatography mass spectrometry
    Gamoh, K
    Prescott, MC
    Goad, LJ
    Takatsuto, S
    BUNSEKI KAGAKU, 1996, 45 (06) : 523 - 527
  • [9] Analysis of antibiotics by liquid chromatography mass spectrometry
    Niessen, WMA
    JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) : 53 - 75
  • [10] Liquid chromatography mass spectrometry in drug analysis
    Sheen, JF
    Her, GR
    JOURNAL OF FOOD AND DRUG ANALYSIS, 1995, 3 (04) : 243 - 258