Quantitative imaging of 124I and 86Y with PET

被引:0
作者
Mark Lubberink
Hans Herzog
机构
[1] Uppsala University Hospital,Department of Medical Physics and PET Centre
[2] Forschungszentrum Jülich,Institute of Neuroscience and Medicine
来源
European Journal of Nuclear Medicine and Molecular Imaging | 2011年 / 38卷
关键词
PET; Positron emission tomography; Y; I; Quantitative imaging; Radionuclide therapy; Dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
The quantitative accuracy and image quality of positron emission tomography (PET) measurements with 124I and 86Y is affected by the prompt emission of gamma radiation and positrons in their decays, as well as the higher energy of the emitted positrons compared to those emitted by 18F. PET scanners cannot distinguish between true coincidences, involving two 511-keV annihilation photons, and coincidences involving one annihilation photon and a prompt gamma, if the energy of this prompt gamma is within the energy window of the scanner. The current review deals with a number of aspects of the challenge this poses for quantitative PET imaging. First, the effect of prompt gamma coincidences on quantitative accuracy of PET images is discussed and a number of suggested corrections are described. Then, the effect of prompt gamma coincidences and the increased singles count rates due to gamma radiation on the count rate performance of PET is addressed, as well as possible improvements based on modification of the scanner’s energy windows. Finally, the effect of positron energy on spatial resolution and recovery is assessed. The methods presented in this overview aim to overcome the challenges associated with the decay characteristics of 124I and 86Y. Careful application of the presented correction methods can allow for quantitatively accurate images with improved image contrast.
引用
收藏
页码:10 / 18
页数:8
相关论文
共 145 条
[1]  
Jentzen W(2010)Experimental investigation of factors affecting the absolute recovery coefficients in iodine-124 PET lesion imaging Phys Med Biol 55 2365-2398
[2]  
Perk LR(2005)(89)Zr as a PET surrogate radioisotope for scouting biodistribution of the therapeutic radiometals (90)Y and (177)Lu in tumor-bearing nude mice after coupling to the internalizing antibody cetuximab J Nucl Med 46 1898-1906
[3]  
Visser GW(1995)Quantitative PET with positron emitters that emit prompt gamma rays IEEE Trans Med Imaging 14 681-687
[4]  
Vosjan MJ(2002)Quantitative imaging and correction for cascade gamma radiation of 76Br with 2D and 3D PET Phys Med Biol 47 3519-3534
[5]  
Stigter-van Walsum M(2003)Quantitation in PET using isotopes emitting prompt single gammas: application to yttrium-86 Eur J Nucl Med Mol Imaging 30 354-361
[6]  
Tijink BM(2003)Quantitative imaging of bromine-76 and yttrium-86 with PET: a method for the removal of spurious activity introduced by cascade gamma rays Med Phys 30 2410-2423
[7]  
Leemans CR(2006)Acquisition settings for PET of 124I administered simultaneously with therapeutic amounts of 131I J Nucl Med 47 1375-1381
[8]  
Martin CC(1961)Aspects of decay of 27Mg and of 89Zr Physica 27 985-993
[9]  
Christian BT(2004)Downscatter contamination from high-energy photons of 124I in 2D and 3D PET IEEE Nucl Sci Symp Conf Rec 6 3629-3633
[10]  
Satter MR(2002)PET quantitation and imaging of the non-pure positron-emitting iodine isotope 124I Appl Radiat Isot 56 673-679