Non-destructive Damage Detection in Fibre Metal Laminates

被引:0
作者
Patryk Jakubczak
Jarosław Bienias
机构
[1] Lublin University of Technology,Department of Materials Engineering, Faculty of Mechanical Engineering
来源
Journal of Nondestructive Evaluation | 2019年 / 38卷
关键词
NDT; Ultrasonic method; Phased array; FML; Fibre metal laminates;
D O I
暂无
中图分类号
学科分类号
摘要
The work explores the possibilities of application of ultrasonic testing in the assessment of fibre metal laminates. Basic problems concerning the use of ultrasonic methods in the research of laminates are explained, and methods for solving these problems are suggested. Tests were conducted using two phased array methods: ultrasonic pulse-echo and through transmission. The efficiency of both selected ultrasonic methods are compared with respect to detecting and dimensioning defects in laminate structures. Based on the analyses and proposed solutions, it has been proven that the developed through transmission phased array (TTPA) method ensures a much more effective, in terms of quality and quantity, assessment of the condition of hybrid laminates than conventional ultrasonic methods, irrespective of the degree of surface deformation and the type of laminate structure.
引用
收藏
相关论文
共 45 条
[1]  
Wu G(2005)The mechanical behavior of GLARE laminates for aircraft structures JOM 57 72-5
[2]  
Yang JM(2000)Development of fibre metal laminates for advanced aerospace structures J. Mater. Process. Technol. 103 1-256
[3]  
Vogelesang LB(2002)Post-impact fatigue damage growth in fiber–metal laminates Int. J. Fatigue 24 249-523
[4]  
Vlot A(1995)New approach for residual compressive strength prediction of impacted CFRP laminates Composites 26 517-143
[5]  
Laliberte JF(2003)Composite defects and their detection Mater. Sci. Eng. 3 103-2078
[6]  
Poon C(2005)X-ray computed microtomography of internal damage in fiber reinforced polymer matrix composites Compos. Sci. Technol. 65 2071-289
[7]  
Straznicky PV(2013)Methods of ultrasonic testing, as an effective way of estimating durability and diagnosing operational capability of composite laminates used in aerospace industry Eksploat I Niezawodn—Maint. Reliab. 15 284-1198
[8]  
Fahr A(1995)Composite structure development decisions using X-ray CT measurements Mater. Eval. 53 203-43
[9]  
Papanicolaou GC(2014)Thermographic inspection of composites Reinf. Plast. 58 42-291
[10]  
Stavropoulos CD(2003)Some inspection methods for quality control and in-service inspection of GLARE Appl. Compos. Mater. 10 277-154