Qualitative analysis of activated sludge using FT-IR technique

被引:0
作者
Michał Kowalski
Katarzyna Kowalska
Jarosław Wiszniowski
Jolanta Turek-Szytow
机构
[1] Silesian University of Technology,Faculty of Energy and Environmental Engineering, Department of Air Protection
[2] German Research Center for Environmental Health,Institute of Epidemiology, Helmholtz Zentrum München
[3] Silesian University of Technology,Faculty of Energy and Environmental Engineering, Environmental Biotechnology Department
[4] Silesian University of Technology,The Biotechnology Center
来源
Chemical Papers | 2018年 / 72卷
关键词
FT-IR; Spectral analysis; Wastewater treatment; Activated sludge; Petroleum compounds;
D O I
暂无
中图分类号
学科分类号
摘要
The ability to measure and control the composition of activated sludge is an important issue, aiming at evaluating the effectiveness of changes occurring in the sludge, what determines its usefulness to treat wastewater. In this research, diffuse reflectance infrared Fourier transform (FTIR–DRIFT) technique was used, which relies on measuring the reflectance of the powdered substance’s surface layer and capturing spectra in range of infrared wave. First, spectra correlation table of the substances mostly occurring in wastewater was developed to assess the main components of the tested samples of activated sludge. The simplest compounds containing functional groups characteristic for particular chemical classes were chosen: peptides (peptone and albumin), fats (glycerin and fatty acids), carbohydrates (glucose and sucrose), nitrogen compounds (NaNO3 and NH4SO4), sulfur compounds (Na2SO4 and Na2S2O3), silicate, etc. The spectra of those substances were captured and characteristic absorption bands for respective bonds in the function groups were assigned. Second, samples of activated sludge from lab-scale membrane bioreactors (MBRs), which purifies petroleum wastewater, were taken. Samples were properly prepared (lyophilization and homogenization) and their spectra were captured. During spectra analysis, previously developed correlation table was used. In obtained spectra of activated sludge, absorption bonds characteristic for amides, peptides, carbohydrates, fats, and aliphatic was identified. The spectra profile of the sludge sample from MBR feed with petroleum wastewater was slightly different from the control MBR sample’s spectra. Intensity of bands in the area characteristic for aliphatic compounds and phenols was clearly higher. This study proves the usefulness of FT-IR technique to observe changes in the chemical composition of activated sludge.
引用
收藏
页码:2699 / 2706
页数:7
相关论文
共 116 条
[1]  
Amir S(2010)Structural study of humic acids during composting of activated sludge-green-waste: elemental analysis, FTIR and J Hazard Mater 177 524-529
[2]  
Jouraiphy A(2013)C NMR Geoderma 209–210 233-240
[3]  
Meddich A(2006)Organic matter composition in soils irrigated with treated wastewater: FT-IR spectroscopic analysis of bulk soil samples Water Sci Technol 53 51-57
[4]  
El Gharous M(2008)Wastewater dissolved organic matter: characteristics and sorptive capabilities Chem Eng Process 47 1106-1117
[5]  
Winterson P(2008)Mapping of protein fouling by FTIR-ATR as experimental tool to study membrane fouling and fluid velocity profile in various geometries and validation by CFD simulation Water Sci Technol 57 1643-1650
[6]  
Hafdi M(2011)Activated sludge process monitoring through in situ NIR spectral analysis Gazette 18 117-124
[7]  
Bernier HM(2003)Kubelka-Munk theory in describing optical properties of paper(I). Tehnički vjesnik—Technical Chemosphere 52 1701-1710
[8]  
Levy GJ(2006)Relation between extracellular polymers’ composition and its ability to complex Cd, Cu and Pb J Hazard Mater 134 190-196
[9]  
Fine P(2017)The reuse of dried activated sludge for adsorption of reactive dye J Hazard Mater 326 120-129
[10]  
Borisover M(2010)Comparison of biomass from integrated fixed-film activated sludge (IFAS), moving bed biofilm reactor (MBBR) and membrane bioreactor (MBR) treating recalcitrant organics: importance of attached biomass Water Res 44 2163-2170