Expert opinion document: "Electrical impedance tomography: applications from the intensive care unit and beyond"

被引:12
|
作者
Rauseo, Michela [1 ]
Spinelli, Elena [2 ]
Sella, Nicolo [3 ]
Slobod, Douglas [2 ,4 ]
Spadaro, Savino [5 ]
Longhini, Federico [6 ]
Giarratano, Antonino [7 ]
Gilda, Cinnella [1 ]
Mauri, Tommaso [2 ,8 ]
Navalesi, Paolo [3 ,9 ]
机构
[1] Univ Foggia, Dept Anesthesia & Intens Care Med, Policlin Riuniti Foggia, Foggia, Italy
[2] CaGranda Osped Maggiore Policlin Milan, Fdn Ist Ricovero & Cura Carattere Sci, Dept Anesthesia Crit Care & Emergency, Milan, Italy
[3] Padua Univ Hosp, Inst Anesthesia & Intens Care, Padua, Italy
[4] McGill Univ, Dept Crit Care Med, Montreal, PQ, Canada
[5] Univ Ferrara, Dept Translat Med, Anesthesia & Intens Care Unit, Ferrara, Italy
[6] Magna Graecia Univ Catanzaro, Mater Domini Univ Hosp, Dept Med & Surg Sci, Anesthesia & Intens Care Unit, Catanzaro, Italy
[7] Univ Palermo, Policlin Paolo Giaccone, Sect Anesthesia Analgesia Intens Care & Emergency, Dept Surg Oncol & Oral Sci Di Chir On S, Palermo, Italy
[8] Univ Milan, Dept Pathophysiol & Transplantat, Milan, Italy
[9] Univ Padua, Dept Med DIMED, Padua, Italy
来源
关键词
EIT; Respiratory monitoring; PEEP; Recruitment maneuvers; Non-invasive ventilation; NIV; CPAP; COVID-19; Intensive care unit; VILI; P-SILI; Operating room; Protective ventilation; Mechanical ventilation; ARDS; COPD; ARF; HFNC; END-EXPIRATORY PRESSURE; MECHANICALLY VENTILATED PATIENTS; RESPIRATORY-DISTRESS-SYNDROME; SPONTANEOUS BREATHING TRIALS; INFLICTED LUNG INJURY; FLOW NASAL CANNULA; NONINVASIVE VENTILATION; ACUTE EXACERBATION; OBESE-PATIENTS; FAILURE;
D O I
10.1186/s44158-022-00055-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Mechanical ventilation is a life-saving technology, but it can also inadvertently induce lung injury and increase morbidity and mortality. Currently, there is no easy method of assessing the impact that ventilator settings have on the degree of lung inssflation. Computed tomography (CT), the gold standard for visually monitoring lung function, can provide detailed regional information of the lung. Unfortunately, it necessitates moving critically ill patients to a special diagnostic room and involves exposure to radiation. A technique introduced in the 1980s, electrical impedance tomography (EIT) can non-invasively provide similar monitoring of lung function. However, while CT provides information on the air content, EIT monitors ventilation-related changes of lung volume and changes of end expiratory lung volume (EELV). Over the past several decades, EIT has moved from the research lab to commercially available devices that are used at the bedside. Being complementary to well-established radiological techniques and conventional pulmonary monitoring, EIT can be used to continuously visualize the lung function at the bedside and to instantly assess the effects of therapeutic maneuvers on regional ventilation distribution. EIT provides a means of visualizing the regional distribution of ventilation and changes of lung volume. This ability is particularly useful when therapy changes are intended to achieve a more homogenous gas distribution in mechanically ventilated patients. Besides the unique information provided by EIT, its convenience and safety contribute to the increasing perception expressed by various authors that EIT has the potential to be used as a valuable tool for optimizing PEEP and other ventilator settings, either in the operative room and in the intensive care unit. The effects of various therapeutic interventions and applications on ventilation distribution have already been assessed with the help of EIT, and this document gives an overview of the literature that has been published in this context.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Chest Electrical Impedance Tomography and Its Clinical Applications
    Zhao, Zhanqi
    Moeller, Knut
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 1250 - 1257
  • [42] CLINICAL-APPLICATIONS OF ELECTRICAL-IMPEDANCE TOMOGRAPHY
    DIJKSTRA, AM
    BROWN, BH
    LEATHARD, AD
    HARRIS, ND
    BARBER, DC
    EDBROOKE, DL
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1993, 17 (03) : 89 - 98
  • [43] AN ANALYSIS OF ELECTRICAL IMPEDANCE TOMOGRAPHY WITH APPLICATIONS TO TIKHONOV REGULARIZATION
    Jin, Bangti
    Maass, Peter
    ESAIM-CONTROL OPTIMISATION AND CALCULUS OF VARIATIONS, 2012, 18 (04) : 1027 - 1048
  • [45] Applications of Electrical Impedance Tomography (EIT): A Short Review
    Bera, Tushar Kanti
    3RD INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS (ICCS-2017), 2018, 331
  • [46] Electrical Impedance Tomography: Hardware Fundamentals And Medical Applications
    Escobar Revelo, Fausto Andrea
    Mosquera Leyton, Victor Hugo
    Rengifo Rodas, Carlos Felipe
    INGENIERIA SOLIDARIA, 2020, 16 (03):
  • [47] Erythropoietin in the intensive care unit: beyond treatment of anemia
    Nimesh SA Patel
    Massimo Collino
    Muhammad M Yaqoob
    Christoph Thiemermann
    Annals of Intensive Care, 1
  • [48] Erythropoietin in the intensive care unit: beyond treatment of anemia
    Patel, Nimesh S. A.
    Collino, Massimo
    Yaqoob, Muhammad M.
    Thiemermann, Christoph
    ANNALS OF INTENSIVE CARE, 2011, 1
  • [49] Guiding nurses from novice to expert: A mentorship program in the surgical intensive care unit
    Rickelmann, C.
    Dickinson, S.
    Wonnacott, R.
    Montanaro, N.
    Litle, M.
    Labeske, M.
    Videan, B.
    Brown, R.
    CRITICAL CARE NURSE, 2007, 27 (02) : 106 - 106
  • [50] AN EXPERT ADVISOR FOR OLIGURIA OCCURRING ON THE INTENSIVE-CARE UNIT
    HOLMAN, JG
    WOLFF, AH
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 1442 - 1443