Expert opinion document: "Electrical impedance tomography: applications from the intensive care unit and beyond"

被引:12
|
作者
Rauseo, Michela [1 ]
Spinelli, Elena [2 ]
Sella, Nicolo [3 ]
Slobod, Douglas [2 ,4 ]
Spadaro, Savino [5 ]
Longhini, Federico [6 ]
Giarratano, Antonino [7 ]
Gilda, Cinnella [1 ]
Mauri, Tommaso [2 ,8 ]
Navalesi, Paolo [3 ,9 ]
机构
[1] Univ Foggia, Dept Anesthesia & Intens Care Med, Policlin Riuniti Foggia, Foggia, Italy
[2] CaGranda Osped Maggiore Policlin Milan, Fdn Ist Ricovero & Cura Carattere Sci, Dept Anesthesia Crit Care & Emergency, Milan, Italy
[3] Padua Univ Hosp, Inst Anesthesia & Intens Care, Padua, Italy
[4] McGill Univ, Dept Crit Care Med, Montreal, PQ, Canada
[5] Univ Ferrara, Dept Translat Med, Anesthesia & Intens Care Unit, Ferrara, Italy
[6] Magna Graecia Univ Catanzaro, Mater Domini Univ Hosp, Dept Med & Surg Sci, Anesthesia & Intens Care Unit, Catanzaro, Italy
[7] Univ Palermo, Policlin Paolo Giaccone, Sect Anesthesia Analgesia Intens Care & Emergency, Dept Surg Oncol & Oral Sci Di Chir On S, Palermo, Italy
[8] Univ Milan, Dept Pathophysiol & Transplantat, Milan, Italy
[9] Univ Padua, Dept Med DIMED, Padua, Italy
来源
关键词
EIT; Respiratory monitoring; PEEP; Recruitment maneuvers; Non-invasive ventilation; NIV; CPAP; COVID-19; Intensive care unit; VILI; P-SILI; Operating room; Protective ventilation; Mechanical ventilation; ARDS; COPD; ARF; HFNC; END-EXPIRATORY PRESSURE; MECHANICALLY VENTILATED PATIENTS; RESPIRATORY-DISTRESS-SYNDROME; SPONTANEOUS BREATHING TRIALS; INFLICTED LUNG INJURY; FLOW NASAL CANNULA; NONINVASIVE VENTILATION; ACUTE EXACERBATION; OBESE-PATIENTS; FAILURE;
D O I
10.1186/s44158-022-00055-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Mechanical ventilation is a life-saving technology, but it can also inadvertently induce lung injury and increase morbidity and mortality. Currently, there is no easy method of assessing the impact that ventilator settings have on the degree of lung inssflation. Computed tomography (CT), the gold standard for visually monitoring lung function, can provide detailed regional information of the lung. Unfortunately, it necessitates moving critically ill patients to a special diagnostic room and involves exposure to radiation. A technique introduced in the 1980s, electrical impedance tomography (EIT) can non-invasively provide similar monitoring of lung function. However, while CT provides information on the air content, EIT monitors ventilation-related changes of lung volume and changes of end expiratory lung volume (EELV). Over the past several decades, EIT has moved from the research lab to commercially available devices that are used at the bedside. Being complementary to well-established radiological techniques and conventional pulmonary monitoring, EIT can be used to continuously visualize the lung function at the bedside and to instantly assess the effects of therapeutic maneuvers on regional ventilation distribution. EIT provides a means of visualizing the regional distribution of ventilation and changes of lung volume. This ability is particularly useful when therapy changes are intended to achieve a more homogenous gas distribution in mechanically ventilated patients. Besides the unique information provided by EIT, its convenience and safety contribute to the increasing perception expressed by various authors that EIT has the potential to be used as a valuable tool for optimizing PEEP and other ventilator settings, either in the operative room and in the intensive care unit. The effects of various therapeutic interventions and applications on ventilation distribution have already been assessed with the help of EIT, and this document gives an overview of the literature that has been published in this context.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Expert opinion document: "Electrical impedance tomography: applications from the intensive care unit and beyond" (vol 2, 28, 2022)
    Rauseo, Michela
    Spinelli, Elena
    Sella, Nicolo
    Slobod, Douglas
    Spadaro, Savino
    Longhini, Federico
    Giarratano, Antonino
    Cinnella, Gilda
    Mauri, Tommaso
    Navalesi, Paolo
    JOURNAL OF ANESTHESIA ANALGESIA AND CRITICAL CARE, 2022, 2 (01):
  • [2] Electrical impedance tomography in the adult intensive care unit: clinical applications and future directions
    Rubin, Jonah
    Berra, Lorenzo
    CURRENT OPINION IN CRITICAL CARE, 2022, 28 (03) : 292 - 301
  • [3] Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
    Alcala, Glasiele C.
    Ekkapat, Gamonmas
    Medeiros, Kyle J.
    Morais, C. A.
    Xin, Yi
    Giammatte, Valentina
    Bruno, Giovanni
    Nova, Alice
    Wanderley, Hatus
    Buhl, Talisa
    Victor, Marcus
    Gaulton, Timothy G.
    La Vita, Carolyn J.
    Amato, Marcelo B. P.
    Ceradda, Maurizio
    Berra, Lorenzo
    Santiago, Roberta Ribeiro De Santis
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (211):
  • [4] Patient examinations using electrical impedance tomography-sources of interference in the intensive care unit
    Frerichs, Inez
    Pulletz, Sven
    Elke, Gunnar
    Gawelczyk, Barbara
    Frerichs, Alexander
    Weiler, Norbert
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (12) : L1 - L10
  • [5] Clinical Scenarios of the Application of Electrical Impedance Tomography in Paediatric Intensive Care
    Davies, Patrick
    Yasin, Samra
    Gates, Simon
    Bird, David
    Silvestre, Catarina
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [6] Clinical Scenarios of the Application of Electrical Impedance Tomography in Paediatric Intensive Care
    Patrick Davies
    Samra Yasin
    Simon Gates
    David Bird
    Catarina Silvestre
    Scientific Reports, 9
  • [7] Expanding intensive care medicine beyond the intensive care unit
    Ken Hillman
    Critical Care, 8
  • [8] Expanding intensive care medicine beyond the intensive care unit
    Hillman, K
    CRITICAL CARE, 2004, 8 (01): : 9 - 10
  • [9] EICU (ELECTRONIC INTENSIVE CARE UNIT) BEYOND INTENSIVE CARE
    Gupta, Shamit
    Kaushal, Anjali
    Dewan, Sandeep
    Varma, Amit
    CRITICAL CARE MEDICINE, 2015, 43 (12)
  • [10] Biomedical applications of electrical impedance tomography
    Bayford, RH
    Lionheart, BRB
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01)