Spatial resolution measurement for iterative reconstruction by use of image-averaging techniques in computed tomography

被引:38
|
作者
Urikura A. [1 ,2 ]
Ichikawa K. [3 ]
Hara T. [4 ]
Nishimaru E. [5 ]
Nakaya Y. [1 ]
机构
[1] Department of Diagnostic Radiology, Shizuoka Cancer Center, Sunto, Shizuoka 411-8777, 1007 Shimonagakubo, Nagaizumi
[2] Graduate School of Medical Science, Kanazawa University, Kanazawa, Ishikawa 920-0942
[3] Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Ishikawa 920-0942
[4] Department of Medical Technology, Nakatsugawa Municipal General Hospital, Nakatsugawa, Gifu 508-0011
[5] Department of Radiology, Hiroshima University Hospital, Minami-ku, Hiroshima 734-8551
关键词
Computed tomography; Dose reduction; Image noise; Iterative reconstruction; MTF; Spatial resolution;
D O I
10.1007/s12194-014-0273-2
中图分类号
学科分类号
摘要
The purpose of our study was to investigate the validity of a spatial resolution measuring method that uses a combination of a bar-pattern phantom and an image-averaging technique, and to evaluate the spatial resolution property of iterative reconstruction (IR) images with middle-contrast (50 HU) objects. We used computed tomography (CT) images of the bar-pattern phantom reconstructed by the IR technology Adaptive Iterative Dose Reduction 3D (AIDR 3D), which was installed in the multidetector CT system Aquilion ONE (Toshiba Medical Systems, Otawara, Japan). The contrast of the bar-pattern image was set to 50 HU, which is considered to be a middle contrast that requires higher spatial resolution clinically. We employed an image-averaging technique to eliminate the influence of image noise, and we obtained averaged images of the bar-pattern phantom with sufficiently low noise. Modulation transfer functions (MTFs) were measured from the images. The conventional wire method was also used for comparison; in this method, AIDR 3D showed MTF values equivalent to those of filtered back projection. For the middle-contrast condition, the results showed that the MTF of AIDR 3D decreased with the strength of IR processing. Further, the MTF of AIDR 3D decreased with dose reduction. The image-averaging technique used was effective for correct evaluation of the spatial resolution for middle-contrast objects in IR images. The results obtained by our method clarified that the resolution preservation of AIDR 3D was not sufficient for middle-contrast objects. © 2014 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:358 / 366
页数:8
相关论文
共 50 条
  • [31] Computationally Efficient System Matrix Calculation Techniques in Computed Tomography Iterative Reconstruction
    Mahmoudi, Golshan
    Ay, Mohammad Reza
    Rahmim, Arman
    Ghadiri, Hossein
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2020, 10 (01): : 1 - 11
  • [32] Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience
    Bittencourt, Marcio Sommer
    Schmidt, Bernhard
    Seltmann, Martin
    Muschiol, Gerd
    Ropers, Dieter
    Daniel, Werner Guenther
    Achenbach, Stephan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) : 1081 - 1087
  • [33] Computed Tomography Image Reconstruction
    Seeram, Euclid
    RADIOLOGIC TECHNOLOGY, 2020, 92 (02) : 155CT - 171CT
  • [34] Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience
    Márcio Sommer Bittencourt
    Bernhard Schmidt
    Martin Seltmann
    Gerd Muschiol
    Dieter Ropers
    Werner Günther Daniel
    Stephan Achenbach
    The International Journal of Cardiovascular Imaging, 2011, 27 : 1081 - 1087
  • [35] Iterative Image Reconstruction Algorithm with Parameter Estimation by Neural Network for Computed Tomography
    Kojima, Takeshi
    Yoshinaga, Tetsuya
    ALGORITHMS, 2023, 16 (01)
  • [36] Image quality comparison of a nonlinear image-based noise reduction technique with a hybrid-type iterative reconstruction for pediatric computed tomography
    Watanabe, Shota
    Ichikawa, Katsuhiro
    Kawashima, Hiroki
    Kono, Yuki
    Kosaka, Hiroyuki
    Yamada, Koji
    Ishii, Kazunari
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 100 - 108
  • [37] Computed tomography imaging with the Adaptive Statistical Iterative Reconstruction (ASIR) algorithm: dependence of image quality on the blending level of reconstruction
    Barca, Patrizio
    Giannelli, Marco
    Fantacci, Maria Evelina
    Caramella, Davide
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (02) : 463 - 473
  • [38] New iterative reconstruction techniques for cardiovascular computed tomography: How do they work, and what are the advantages and disadvantages?
    Nelson, Rendon C.
    Feuerlein, Sebastian
    Boll, Daniel T.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (05) : 286 - 292
  • [39] Adaptive statistical iterative reconstruction for volume-rendered computed tomography portovenography: improvement of image quality
    Matsuda, Izuru
    Hanaoka, Shohei
    Akahane, Masaaki
    Sato, Jiro
    Komatsu, Shuuhei
    Inoh, Shinichi
    Kiryu, Shigeru
    Yoshioka, Naoki
    Ino, Kenji
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (09): : 700 - 706
  • [40] Hybrid Iterative Reconstruction for Low Radiation Dose Computed Tomography
    Sheng, Jinhua
    Chen, Bin
    Wang, Bocheng
    Liu, Qingqiang
    Ma, Yangjie
    Liu, Weixiang
    NEURAL INFORMATION PROCESSING (ICONIP 2018), PT VI, 2018, 11306 : 243 - 256