Stability Evaluation and Calibration of Type C Thermocouples at the Pt–C Eutectic Fixed Point

被引:1
作者
Jianping Sun
Xiaofeng Lu
Meng Ye
Wei Dong
Yalu Niu
机构
[1] National Institute of Metrology,
[2] Xi’an Polytechnic University,undefined
[3] Taiyuan University of Technology,undefined
来源
International Journal of Thermophysics | 2017年 / 38卷
关键词
Calibration; Pt–C eutectic fixed point; Stability; Tungsten–rhenium thermocouple;
D O I
暂无
中图分类号
学科分类号
摘要
Tungsten–rhenium thermocouples (type C thermocouples) are used to measure temperatures higher than 1500 ∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${^{\circ }}$$\end{document}C under protective, inert, or vacuum conditions in a wide range of industries, such as metallurgy, power generation, and aerospace. Generally, the measurement uncertainty of a new tungsten–rhenium thermocouple is about 1 % (20 ∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${^{\circ }}$$\end{document}C at 2000 ∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${^{\circ }}$$\end{document}C), and a significant drift is always observed above 1200 ∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${^{\circ }}$$\end{document}C. Recently, the National Institute of Metrology, China, has spent great efforts to calibrate tungsten–rhenium thermocouples with high-temperature fixed points of up to 2000 ∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${^{\circ }}$$\end{document}C. In the present work, three tungsten–rhenium thermocouples made by two manufacturers were calibrated at the Pt–C eutectic fixed point (1738 ∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${^{\circ }}$$\end{document}C) and their stability was investigated. A linear fitting and extrapolation method was developed to determine the melting and freezing temperatures of the Pt–C eutectic fixed point for avoiding the effect of thermal resistance caused by the sheath and protection tube. The results show that the repeatability of the calibration is better than 0.9 ∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${^{\circ }}$$\end{document}C from the melting curve of the Pt–C fixed point and better than 1.2 ∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${^{\circ }}$$\end{document}C from the freezing curve of the Pt–C fixed point, and a good agreement was obtained for the calibration with the melting and freezing temperature plateau through the linear fitting and extrapolation method. The calibration uncertainty of the thermocouples at the Pt–C eutectic fixed point was 3.1 ∘\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${^{\circ }}$$\end{document}C (k =\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$=$$\end{document} 2).
引用
收藏
相关论文
共 35 条
[11]  
Edler F(undefined)undefined undefined undefined undefined-undefined
[12]  
Morice R(undefined)undefined undefined undefined undefined-undefined
[13]  
Pearce J(undefined)undefined undefined undefined undefined-undefined
[14]  
Edler F(undefined)undefined undefined undefined undefined-undefined
[15]  
Baratto AC(undefined)undefined undefined undefined undefined-undefined
[16]  
Kim YG(undefined)undefined undefined undefined undefined-undefined
[17]  
Yang I(undefined)undefined undefined undefined undefined-undefined
[18]  
Kwon SY(undefined)undefined undefined undefined undefined-undefined
[19]  
Gam KS(undefined)undefined undefined undefined undefined-undefined
[20]  
Yokoyama DT(undefined)undefined undefined undefined undefined-undefined