Discrimination model applied to urinalysis of patients with diabetes and hypertension aiming at diagnosis of chronic kidney disease by Raman spectroscopy

被引:0
作者
Elzo Everton de Souza Vieira
Jeyse Aliana Martins Bispo
Landulfo Silveira
Adriana Barrinha Fernandes
机构
[1] Faculdades Integradas do Tapajós – FIT,Biomedical Engineering Center
[2] Universidade Camilo Castelo Branco-UNICASTELO,undefined
[3] Biomedical Engineering Institute,undefined
[4] Parque Tecnológico de São José dos Campos,undefined
[5] Universidade Anhembi Morumbi – UAM,undefined
[6] Parque Tecnológico de São José dos Campos,undefined
[7] Center of Innovation,undefined
[8] Technology and Education – CITE,undefined
[9] Parque Tecnológico de São José dos Campos,undefined
来源
Lasers in Medical Science | 2017年 / 32卷
关键词
Raman spectroscopy; Mahalanobis distance; Urinalysis; Diabetes; Hypertension; Chronic kidney disease;
D O I
暂无
中图分类号
学科分类号
摘要
Higher blood pressure level and poor glycemic control in diabetic patients are considered progression factors that cause faster decline in kidney functions leading to kidney damage. The present study aimed to develop a quantification model of biomarkers creatinine, urea, and glucose by means of selected peaks of these compounds, measured by Raman spectroscopy, and to estimate the concentration of these analytes in the urine of normal subjects (G_N), diabetic patients with hypertension (G_WOL) patients with chronic renal failure doing dialysis (G_D). Raman peak intensities at 680 cm−1 (creatinine), 1004 cm−1 (urea), and 1128 cm−1 (glucose) from normal, diabetic, and hypertensive and doing dialysis patients, obtained with a dispersive 830 nm Raman spectrometer, were estimated through Origin software. Spectra of creatinine, urea, and glucose diluted in water were also obtained, and the same peaks were evaluated. A discrimination model based on Mahalanobis distance was developed. It was possible to determine the concentration of creatinine, urea, and glucose by means of the Raman peaks of the selected biomarkers in the urine of the groups G_N, G_WOL, and G_D (r = 0.9). It was shown that the groups G_WOL and G_D had lower creatinine and urea concentrations than the group G_N (p < 0.05). The classification model based on Mahalanobis distance applied to the concentrations of creatinine, urea, and glucose presented a correct classification of 89% for G_N, 86% for G_WOL, and 79% for G_D. It was possible to obtain quantitative information regarding important biomarkers in urine for the assessment of renal impairment in patients with diabetes and hypertension, and this information can be correlated with clinical criteria for the diagnosis of chronic kidney disease.
引用
收藏
页码:1605 / 1613
页数:8
相关论文
共 79 条
  • [1] Eknoyan G(2004)The burden of kidney disease: improving global outcomes Kidney Int 66 1310-1314
  • [2] Lameire N(2011)Chronic dialysis in Brazil—report of the Brazilian dialysis census J Bras Nefrol 34 272-277
  • [3] Barsoum R(2003)K/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification and stratification Am J Kidney Dis 39 1-266
  • [4] Eckardt KU(1986)Uber den niederschlag welchen pikrinsaure in normalen harn erzeugt und uber eine neue reaktion des kreatinins Hoppe Seyler's Z Physiol Chem 10 391-400
  • [5] Levin A(2011)Chronic kidney disease: importance of early diagnosis, immediate referral and structured interdisciplinary approach to improve outcomes in patients not yet on dialysis J Bras Nefrol 22 93-108
  • [6] Locatelli F(2000)Prospects for in vivo Raman spectroscopy Phys Med Biol 45 R1-R59
  • [7] Sesso RCC(2016)Estimating the concentration of urea and creatinine in the human serum of normal and dialysis patients through Raman spectroscopy Lasers Med Sci 31 1415-1423
  • [8] Lopes AA(2003)Raman spectroscopy-based creatinine measurement in urine samples from a multipatient population Appl Spectrosc 57 522-525
  • [9] Thomé FS(2016)Quantifying creatinine and urea in human urine through Raman spectroscopy aiming at diagnosis of kidney disease J Biomed Opt 21 37001-334
  • [10] Lugon JR(2001)Urine analysis by laser Raman spectroscopy Lasers Surg Med 28 330-39