Shear wave elastography in chronic kidney disease – the physics and clinical application

被引:0
|
作者
Kwan Hoong Ng
Jeannie Hsiu Ding Wong
Sook Sam Leong
机构
[1] Universiti Malaya,Department of Biomedical Imaging, Faculty of Medicine
[2] UCSI University,Faculty of Medicine and Health Sciences
[3] Universiti Teknologi MARA Selangor,Centre for Medical Imaging Studies, Faculty of Health Sciences
来源
Physical and Engineering Sciences in Medicine | 2024年 / 47卷
关键词
Shear wave; Elastography; Physics; Ultrasound; Kidney; Imaging;
D O I
暂无
中图分类号
学科分类号
摘要
Chronic kidney disease is a leading public health problem worldwide. The global prevalence of chronic kidney disease is nearly five hundred million people, with almost one million deaths worldwide. Estimated glomerular filtration rate, imaging such as conventional ultrasound, and histopathological findings are necessary as each technique provides specific information which, when taken together, may help to detect and arrest the development of chronic kidney disease, besides managing its adverse outcomes. However, estimated glomerular filtration rate measurements are hampered by substantial error margins while conventional ultrasound involves subjective assessment. Although histopathological assessment is the best tool for evaluating the severity of the renal pathology, it may lead to renal insufficiency and haemorrhage if complications occurred. Ultrasound shear wave elastography, an emerging imaging that quantifies tissue stiffness non-invasively has gained interest recently. This method applies acoustic force pulses to generate shear wave within the tissue that propagate perpendicular to the main ultrasound beam. By measuring the speed of shear wave propagation, the tissue stiffness is estimated. This paper reviews the literature and presents our combined experience and knowledge in renal shear wave elastography research. It discusses and highlights the confounding factors on shear wave elastography, current and future possibilities in ultrasound renal imaging and is not limited to new sophisticated techniques.
引用
收藏
页码:17 / 29
页数:12
相关论文
共 50 条
  • [31] Shear wave elastography accurately detects chronic changes in renal histopathology
    Leong, Sook Sam
    Wong, Jeannie Hsiu Ding
    Md Shah, Mohammad Nazri
    Vijayananthan, Anushya
    Jalalonmuhali, Maisarah
    Chow, Tak Kuan
    Sharif, Nur H. M.
    Ng, Kwan Hoong
    NEPHROLOGY, 2021, 26 (01) : 38 - 45
  • [32] Correlation of Point Shear Wave Velocity and Kidney Function in Chronic Kidney Disease
    Grosu, Iulia
    Bob, Flaviu
    Sporea, Ioan
    Popescu, Alina
    Sirli, Roxana
    Schiller, Adalbert
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (11) : 2613 - 2620
  • [33] Clinical relevance of shear wave elastography compared with transient elastography and other markers of liver fibrosis
    Ayonrinde, Oyekoya T.
    Zelesco, Marilyn
    Welman, Christopher J.
    Abbott, Steven
    Adris, Niwansa
    INTERNAL MEDICINE JOURNAL, 2022, 52 (04) : 640 - 650
  • [34] An evaluation with shear wave elastography of kidney elasticity in patients with familial Mediterranean fever
    Kayali, Alperen
    Keles, Fatma Ozturk
    Seyfettin, Ayca
    Dirican, Emre
    Celik, Muhammed Murat
    JOURNAL OF CLINICAL ULTRASOUND, 2023, 51 (01) : 177 - 183
  • [35] Association of renal elasticity evaluated by real-time shear wave elastography with renal fibrosis in patients with chronic kidney disease
    Chen, Ziman
    Wang, Yingli
    Ying, Michael Tin Cheung
    Su, Zhongzhen
    Han, Xinyang
    Gunda, Simon Takadiyi
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1154): : 392 - 398
  • [36] In silico analysis reveals the prospects of renal anisotropy in improving chronic kidney disease detection using ultrasound shear wave elastography
    Lim, William T. H.
    Ooi, Ean H.
    Foo, Ji J.
    Ng, Kwan H.
    Wong, Jeannie H. D.
    Leong, Sook S.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (09)
  • [37] Application of Shear Wave Elastography in the Diagnosis of Thyroid Nodules of Thyroid Imaging Report and Data System
    Zheng, Jia
    Wang, Xiaoxin
    Han, Xianjing
    Li, Chunyan
    Wang, Jianan
    Zhao, Huiji
    Liang, Guoxin
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (04) : 864 - 867
  • [38] Clinical application of shear wave elastography (SWE) in the diagnosis of benign and malignant breast diseases
    Chang, Jung Min
    Moon, Woo Kyung
    Cho, Nariya
    Yi, Ann
    Koo, Hye Ryoung
    Han, Wonsik
    Noh, Dong-Young
    Moon, Hyeong-Gon
    Kim, Seung Ja
    BREAST CANCER RESEARCH AND TREATMENT, 2011, 129 (01) : 89 - 97
  • [39] Shear wave elastography of the tibial nerve in healthy subjects
    Bedewi, Mohamed A.
    Elsifey, Ayman A.
    Alfaifi, Tariq
    Kotb, Mamdouh A.
    Abdelgawad, Mohamed S.
    Bediwy, Abdelmohsen Mohamed
    Swify, Sherine Mohamed
    Awad, Ezzat M.
    MEDICINE, 2021, 100 (03) : E23999
  • [40] Shear wave elastography of the radial nerve in healthy subjects
    Bedewi, Mohamed A.
    Kotb, Mamdouh A.
    Aldossary, Nasser M.
    Abodonya, Ahmed M.
    Saleh, Ayman K.
    Swify, Sherine Mohamed
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (01)