C-arm CT-guided 3D navigation of percutaneous interventions

被引:7
作者
Becker, H-C [1 ]
Meissner, O. [1 ]
Waggershauser, T. [1 ]
机构
[1] Klinikum Ludwig Maximilians Univ Munchen, Inst Klin Radiol, D-81377 Munich, Germany
来源
RADIOLOGE | 2009年 / 49卷 / 09期
关键词
C-arm computed tomography; 3D navigation; Percutaneous intervention; Vertebroplasty; Radiofrequency ablation; CONE-BEAM CT; VERTEBROPLASTY; ANEURYSM; LESIONS; REPAIR;
D O I
10.1007/s00117-009-1866-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
So far C-arm CT images were predominantly used for a precise guidance of an endovascular or intra-arterial therapy. A novel combined 3D-navigation C-arm system now also allows cross-sectional and fluoroscopy controlled interventions. Studies have reported about successful CT-image guided navigation with C-arm systems in vertebroplasty. Insertion of the radiofrequency ablation probe is also conceivable for lung and liver tumors that had been labelled with lipiodol. In the future C-arm CT based navigation systems will probably allow simplified and safer complex interventions and simultaneously reduce radiation exposure.
引用
收藏
页码:852 / 855
页数:4
相关论文
共 10 条
[1]   Intraoperative DynaCT Detection and Immediate Correction of a Type 1a Endoleak Following Endovascular Repair of Abdominal Aortic Aneurysm [J].
Biasi, Lukla ;
Ali, Tahir ;
Hinchliffe, Robert ;
Morgan, Rob ;
Loftus, Ian ;
Thompson, Matt .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (03) :535-538
[2]   Initial observations of endovascular aneurysm repair using Dyna-CT [J].
Eide, Kari Ravn ;
Odegard, Asbjorn ;
Myhre, Hans Olav ;
Haraldseth, Olav .
JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (01) :50-53
[3]   Usefulness of Cone-Beam CT Before and After Percutaneous Vertebroplasty [J].
Hiwatashi, Akio ;
Yoshiura, Takashi ;
Noguchi, Tomoyuki ;
Togao, Osamu ;
Yamashita, Koji ;
Kamano, Hironori ;
Honda, Hiroshi .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (05) :1401-1405
[4]   Flat-detector computed tomography (FD-CT) [J].
Kalender, Willi A. ;
Kyriakou, Yiannis .
EUROPEAN RADIOLOGY, 2007, 17 (11) :2767-2779
[5]   C-arm cone-beam CT: Applications for spinal cement augmentation demonstrated by three cases [J].
Knight, Jesse R. ;
Heran, Manraj ;
Munk, Peter L. ;
Raabe, Rodney ;
Liu, David M. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (07) :1118-1122
[6]  
MEYER BC, 2009, EUR RADIOL IN PRESS
[7]   Visualization of hypervascular liver lesions during TACE: Comparison of angiographic C-arm CT and MDCT [J].
Meyer, Bernhard C. ;
Frericks, Bernd B. ;
Voges, Maerthe ;
Borchert, Michael ;
Martus, Peter ;
Justiz, Joern ;
Wolf, Karl-Juergen ;
Wacker, Frank K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) :W263-W269
[8]   Flat-panel CT as a new perinterventional imaging modality in aortic stentgraft procedures - Work in progress [J].
Rabitsch, E. ;
Celedin, S. ;
Kau, T. ;
Illiasch, H. ;
Hausegger, K. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (02) :127-133
[9]  
Rand T, 2003, RADIOLOGE, V43, P723, DOI 10.1007/s00117-003-0948-x
[10]  
Rogalla P, 2004, RADIOLOGE, V44, P671, DOI 10.1007/s00117-004-1076-y