Zero valent Fe-reduced graphene oxide quantum dots as a novel magnetic dispersive solid phase microextraction sorbent for extraction of organophosphorus pesticides in real water and fruit juice samples prior to analysis by gas chromatography-mass spectrometry

被引:0
作者
Samaneh Akbarzade
Mahmoud Chamsaz
Gholam Hossein Rounaghi
Mahdi Ghorbani
机构
[1] Ferdowsi University of Mashhad,Department of Chemistry, Faculty of Sciences
来源
Analytical and Bioanalytical Chemistry | 2018年 / 410卷
关键词
Zero valent Fe-reduced graphene oxide quantum dots; Organophosphorus pesticides; Magnetic dispersive solid-phase microextraction; Gas chromatography-mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
A selective and sensitive magnetic dispersive solid-phase microextraction (MDSPME) coupled with gas chromatography-mass spectrometry was developed for extraction and determination of organophosphorus pesticides (Sevin, Fenitrothion, Malathion, Parathion, and Diazinon) in fruit juice and real water samples. Zero valent Fe-reduced graphene oxide quantum dots (rGOQDs@ Fe) as a new and effective sorbent were prepared and applied for extraction of organophosphorus pesticides using MDSPME method. In order to study the performance of this new sorbent, the ability of rGOQDs@ Fe was compared with graphene oxide and magnetic graphene oxide nanocomposite by recovery experiments of the organophosphorus pesticides. Several affecting parameters in the microextraction procedure, including pH of donor phase, donor phase volume, stirring rate, extraction time, and desorption conditions such as the type and volume of solvents and desorption time were thoroughly investigated and optimized. Under the optimal conditions, the method showed a wide linear dynamic range with R-square between 0.9959 and 0.9991. The limit of detections, the intraday and interday relative standard deviations (n = 5) were less than 0.07 ngmL–1, 4.7, and 8.6%, respectively. The method was successfully applied for extraction and determination of organophosphorus pesticides in real water samples (well, river and tap water) and fruit juice samples (apple and grape juice). The obtained relative recoveries were in the range of 82.9%–113.2% with RSD percentages of less than 5.8% for all the real samples.
引用
收藏
页码:429 / 439
页数:10
相关论文
共 130 条
[1]  
Yang Y(2014)Acetylcholinesterase biosensor based on a gold nanoparticle–polypyrrole–reduced graphene oxide nanocomposite modified electrode for the amperometric detection of organophosphorus pesticides Analyst 139 3055-3060
[2]  
Asiri AM(2016)Homogeneous liquid–liquid microextraction for determination of organophosphorus pesticides in environmental water samples prior to gas chromatography-flame photometric detection J Chromatogr Sci 54 1061-1067
[3]  
Du D(2014)Rapid and effective sample clean-up based on magnetic multiwalled carbon nanotubes for the determination of pesticide residues in tea by gas chromatography–mass spectrometry Food Chem 145 853-858
[4]  
Lin Y(2014)Nanomaterial-based biosensors for environmental and biological monitoring of organophosphorus pesticides and nerve agents Trends Anal Chem 54 1-10
[5]  
Berijani S(2013)A simple and sensitive fluorescence biosensor for detection of organophosphorus pesticides using H 2 O 2-sensitive quantum dots/bi-enzyme Biosens Bioelectron 47 402-407
[6]  
Sadigh M(2016)Glycine functionalized multiwall carbon nanotubes as a novel hollow fiber solid-phase microextraction sorbent for pre-concentration of venlafaxine and o-desmethylvenlafaxine in biological and water samples prior to determination by high-performance liquid chromatography Anal Bioanal Chem 408 4247-4256
[7]  
Pournamdari E(2016)Ultrasound-assisted magnetic dispersive solid-phase microextraction: a novel approach for the rapid and efficient microextraction of naproxen and ibuprofen employing experimental design with high-performance liquid chromatography J Sep Sci 39 1082-1089
[8]  
Deng X(2014)Graphene oxide-based dispersive micro-solid phase extraction for separation and preconcentration of nicotine from biological and environmental water samples followed by gas chromatography-flame ionization detection Talanta 130 71-77
[9]  
Guo Q(2014)Graphene oxide-based microspheres for the dispersive solid-phase extraction of nonsteroidal estrogens from water samples J Chromatogr A 1368 18-25
[10]  
Chen X(2015)A novel dispersive micro solid phase extraction using PCX as the sorbent for the determination of melamine and cyromazine in milk and milk powder by UHPLC-HRMS/MS Talanta 134 144-152