Detection of GI and GII Noroviruses in Ground Water Using Ultrafiltration and TaqMan Real-time RT-PCR

被引:0
作者
Vincent R. Hill
Bonnie Mull
Narayanan Jothikumar
Karen Ferdinand
Jan Vinjé
机构
[1] Centers for Disease Control and Prevention,Division of Foodborne, Waterborne, and Environmental Diseases
[2] National Center for Emerging and Zoonotic Infectious Diseases,Division of Viral Diseases
[3] CDC,undefined
[4] National Center for Immunization and Respiratory Diseases,undefined
[5] Atlanta Research and Education Foundation,undefined
来源
Food and Environmental Virology | 2010年 / 2卷
关键词
Norovirus; Ground water; Ultrafiltration; Real-time RT-PCR;
D O I
暂无
中图分类号
学科分类号
摘要
Noroviruses (NoVs) are a leading cause of epidemic and sporadic acute gastrointestinal illness globally. These viruses can potentially contaminate rural private wells and non-community drinking water systems, and cause waterborne disease outbreaks related to consumption of contaminated ground water. Detection of NoVs in water samples can be challenging because they are genetically and antigenically diverse, and noncultivable. In the present study, the detection limits of a novel broadly reactive GI assay and an existing GII NoV real-time TaqMan reverse transcriptase-polymerase chain reaction (RT-qPCR) assay in ground water concentrates was determined. Ground water samples (50 l) from two sources (Lawrenceville, GA and Gainesville, FL, USA) were seeded with electron microscopy-enumerated and RT-qPCR quantified NoV and concentrated using hollow-fiber ultrafiltration (UF) followed by either polyethylene glycol (PEG) precipitation or microconcentrators. Detection limits for GI NoV ranged from 1 × 104 (GA source) to 2 × 105 (FL source) virus particles in 50 l water samples (corresponding to 200–3,000 particles/l) and 5 × 104 (GA source) to 5 × 105 (FL source) virus particles (corresponding to 1,000–10,000 particles/l) for GII NoV. The reported UF method, sample processing procedures, and RT-qPCR assays should be effective tools for sensitive detection of NoVs in large-volume water samples.
引用
收藏
页码:218 / 224
页数:6
相关论文
共 156 条
[1]  
Baert L(2008)Evaluation of viral extraction methods on a broad range of ready-to-eat foods with conventional and real-time RT-PCR for Norovirus GII detection International Journal of Food Microbiology 123 101-108
[2]  
Uyttendaele M(2010)Diagnostic accuracy and analytical sensitivity of IDEIA norovirus assay for routine screening of human norovirus Journal of Clinical Microbiology 48 2770-2778
[3]  
Debevere J(2009)Norovirus detection in groundwater Food and Environmental Virology 1 92-96
[4]  
Costantini V(2009)Norovirus distribution within an estuarine environment Applied and Environmental Microbiology 75 5474-5480
[5]  
Grenz L(2009)A rapid and efficient method for quantitation of genogroups I and II norovirus from oysters and application in other complex environmental samples Journal of Virological Methods 156 59-65
[6]  
Fritzinger A(2009)Norovirus gastroenteritis New England Journal of Medicine 361 1776-1785
[7]  
Lewis D(1986)Humic-acid interference with virus recovery by electropositive microporous filters Applied and Environmental Microbiology 52 556-561
[8]  
Biggs C(2009)Detection of human viruses in rivers of a densly-populated area in Germany using a virus adsorption elution method optimized for PCR analyses Water Research 43 2657-2668
[9]  
Hale A(2009)Detection and characterization of hepatitis A virus and norovirus in estuarine water samples using ultrafiltration—RT-PCR integrated methods Journal of Applied Microbiology 106 1579-1590
[10]  
Vinje J(2007)Gastroenteritis outbreak caused by waterborne norovirus at a New Zealand ski resort Applied and Environmental Microbiology 73 7853-7857