The implementation of data reconciliation for evaluating a full-scale petrochemical wastewater treatment plant

被引:0
作者
Ali Behnami
Mohammad Shakerkhatibi
Reza Dehghanzadeh
Khaled Zoroufchi Benis
Siavash Derafshi
Esmaeil Fatehifar
机构
[1] Tabriz University of Medical Sciences,Department of Environmental Health Engineering, School of Health, Student Research Committee
[2] Tabriz University of Medical Sciences,Department of Environmental Health Engineering, School of Health
[3] Sahand University of Technology,Faculty of Chemical Engineering
[4] Tabriz petrochemical CO.,Office of Health Safety and Environment
来源
Environmental Science and Pollution Research | 2016年 / 23卷
关键词
Performance evaluation; Wastewater; Petrochemical; Activated sludge; Data reconciliation;
D O I
暂无
中图分类号
学科分类号
摘要
Data reconciliation and mass balance analysis were conducted for the first time to improve the data obtained from a petrochemical wastewater treatment plant (WWTP), and the results were applied to evaluate the performance of the plant. Daily average values for 209 days from the inlet and outlet of the plant obtained from WWTP documentation center along with the results of four sampling runs in this work were used for data reconciliation and performance evaluation of the plant. Results showed that standard deviation and relative errors in the balanced data of each measurement decreased, especially for the process wastewater from 24.5 to 8.6 % for flow and 24.5 to 1.5 % for chemical oxygen demand (COD). The errors of measured data were −137 m3/day (−4.41 %) and 281 kg/day (7.92 %) for flow and COD, respectively. According to the balanced data, the removal rates of COD and 5-day biological oxygen demand (BOD5) through the aeration unit were equal to 37 and 46 %, respectively. In addition, the COD and BOD5 concentrations were reduced by about 61.9 % (2137 kg/day) and 78.1 % (1976 kg/day), respectively, prior to the biological process. At the same time, the removal rates of benzene, toluene, and styrene were 56, 38, and 69 %, respectively. The results revealed that about 40 % of influent benzene (75.5 kg/day) is emitted to the ambient air at the overhead of the equalization basin. It can be concluded that the volatilization of organic compounds is the basic mechanism for the removal of volatile organic compounds (VOCs) and it corresponds to the main part of total COD removal from the WWTP.
引用
收藏
页码:22586 / 22595
页数:9
相关论文
共 140 条
[1]  
Ahmadi M(2013)Performance evaluation of moving bed bio film reactor in saline wastewater treatment Iran J Healt Sci 1 58-64
[2]  
Alavi N(2008)Evaluation study of a slaughterhouse wastewater treatment plant including contact-assisted activated sludge and DAF Desalination 225 167-175
[3]  
Jaafarzadeh N(2008)Volatile organic compound emissions from wastewater treatment plants in Taiwan: legal regulations and costs of control J Environ Manag 88 1485-1494
[4]  
Barfar M(2006)Evaluation of municipal wastewater treatment plants with different technologies at las Rozas, Madrid (Spain J Environ Manag 81 399-404
[5]  
Ghaedrahmat Z(1983)Reconciliation of process flow rates by matrix projection. Part I: linear case AICHE J 29 881-888
[6]  
Hashemi F(2007)Long-term operating performance of a poultry slaughterhouse wastewater treatment plant Resour Conserv Recy 50 102-114
[7]  
Al-Mutairi NZ(2013)Optimization of membrane bioreactors for the treatment of petrochemical wastewater under transient conditions Chem Eng Trans 32 7-12
[8]  
Al-Sharifi FA(2012)Performance simulation of H-TDS unit of FAJR industrial wastewater treatment plant using a combination of neural network and principal component analysis J Water Resource Prot 4 311-317
[9]  
Al-Shammari SB(2015)Performance of three small-scale wastewater treatment plants. A challenge for possible re use Environ Sci Pollut Res 22 17744-17752
[10]  
Cheng WH(2015)Assessment of environmental data quality and its effect on modelling error of full-scale plants with a closed-loop mass balancing Environ Technol 36 3253-3261