Study of the cyclic loss rate of 220Rn progeny in a 220Rn chamber by an airflow model

被引:0
|
作者
Huanhui Huang
Guiyuan Li
Qingzhi Zhou
Weijie Sun
Tong Wu
Shaohua Hu
机构
[1] University of South China,School of Nuclear Science and Technology
来源
Journal of Radioanalytical and Nuclear Chemistry | 2023年 / 332卷
关键词
Rn progeny; Rn chamber; Fan frequency; Aerosol particle; Cyclic loss rate;
D O I
暂无
中图分类号
学科分类号
摘要
To accurately measure and evaluate the radiation dose of 220Rn and its progeny, a 220Rn chamber with an airflow model has been developed and studied, but it is difficult to take into consideration many relevant factors such as adsorption, wall attachment, and decay. This paper proposes the concept of cyclic loss rate of 220Rn progeny based on progeny supplement technology, establishes a theoretical formula to calculate the cyclic loss rate, and analyzes the relationship between cyclic loss rate, fan frequency, and aerosol particle size through both experiments and modelling methods. The feasibility of the cyclic loss rate model is experimentally verified.
引用
收藏
页码:2633 / 2641
页数:8
相关论文
共 50 条
  • [32] Concentrations of 222Rn and 220Rn in indoor air
    Vaupotic, Janja
    Celikovic, Igor
    Smrekar, Natasa
    Zunic, Zora S.
    Kobal, Ivan
    ACTA CHIMICA SLOVENICA, 2008, 55 (01) : 160 - 165
  • [33] 222Rn and 220Rn diffusion in two mediums
    Markovic, V. M.
    Nikezic, D.
    Stevanovic, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 857 : 16 - 23
  • [34] Measuring thoron (220Rn) in natural waters
    Burnett, W. C.
    Dimova, N.
    Dulaiova, H.
    Lane-Smith, D.
    Parsa, B.
    Szabo, Z.
    ENVIRONMENTAL RADIOCHEMICAL ANALYSIS III, 2007, (312): : 24 - +
  • [35] Thoron (220Rn) detection with plastic scintillators
    Mitev, Krasimir K.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [36] Why is 220Rn (thoron) measurement important?
    Tokonami, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) : 335 - 339
  • [37] 小220Rn室的研究
    肖德涛
    赵桂芝
    肖拥军
    马光鼐
    核电子学与探测技术, 2005, (06) : 11 - 13
  • [38] A STUDY OF DISEQUILIBRIUM BETWEEN 220Rn AND 216Po FOR 220Rn MEASUREMENTS USING A FLOW-THROUGH LUCAS SCINTILLATION CELL
    Sathyabama, N.
    Datta, D.
    Gaware, J. J.
    Mayya, Y. S.
    Tripathi, R. M.
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (02) : 187 - 194
  • [39] The improvement of the method of 220Rn density adjustment
    Shool of Nuclear Science and Technology, Nanhua University, Hengyang 421001, China
    Hedianzixue Yu Tance Jishue, 2007, 3 (592-593+528):
  • [40] On the emanation of thoron (220Rn) from precipitates
    Huxol, Stephan
    Hoehn, Eduard
    Surbeck, Heinz
    Kipfer, Rolf
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A565 - A565