Study of the cyclic loss rate of 220Rn progeny in a 220Rn chamber by an airflow model

被引:0
|
作者
Huanhui Huang
Guiyuan Li
Qingzhi Zhou
Weijie Sun
Tong Wu
Shaohua Hu
机构
[1] University of South China,School of Nuclear Science and Technology
来源
Journal of Radioanalytical and Nuclear Chemistry | 2023年 / 332卷
关键词
Rn progeny; Rn chamber; Fan frequency; Aerosol particle; Cyclic loss rate;
D O I
暂无
中图分类号
学科分类号
摘要
To accurately measure and evaluate the radiation dose of 220Rn and its progeny, a 220Rn chamber with an airflow model has been developed and studied, but it is difficult to take into consideration many relevant factors such as adsorption, wall attachment, and decay. This paper proposes the concept of cyclic loss rate of 220Rn progeny based on progeny supplement technology, establishes a theoretical formula to calculate the cyclic loss rate, and analyzes the relationship between cyclic loss rate, fan frequency, and aerosol particle size through both experiments and modelling methods. The feasibility of the cyclic loss rate model is experimentally verified.
引用
收藏
页码:2633 / 2641
页数:8
相关论文
共 50 条
  • [1] Study of the cyclic loss rate of 220Rn progeny in a 220Rn chamber by an airflow model
    Huang, Huanhui
    Li, Guiyuan
    Zhou, Qingzhi
    Sun, Weijie
    Wu, Tong
    Hu, Shaohua
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2023, 332 (07) : 2633 - 2641
  • [2] Regulation and control methods for the unattached fraction of 220Rn progeny in a 220Rn progeny chamber
    Lin, Jian
    Xiao, Detao
    He, Zhengzhong
    Li, Shicheng
    Zhang, Yuanyuan
    Wang, Zhen
    Yu, Bo
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2021, 235
  • [3] Estimation of indoor 220Rn progeny concentrations with 220Rn measurements
    Zhuo, W.
    Chen, B.
    Wei, M.
    RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) : 408 - 411
  • [4] Behavior of 220Rn progeny in diffusion chamber
    Nikezic, D.
    Stevanovic, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 570 (01): : 182 - 186
  • [5] Development of an aerosol chamber for calibration of 220Rn progeny detectors
    Sorimachi, Atsuyuki
    Ishikawa, Tetsuo
    Tokonami, Shinji
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (09):
  • [6] 220Rn and its progeny in dwellings of Korea
    Kim, Chang-Kyu
    Kim, Young-Jae
    Lee, Hwa-Yong
    Chang, Byung-Uck
    Tokonami, Shinji
    RADIATION MEASUREMENTS, 2007, 42 (08) : 1409 - 1414
  • [7] 220Rn室中220Rn浓度的调控研究
    刘良军
    南华大学学报(自然科学版), 2007, (02) : 16 - 19
  • [8] A study of 222Rn/220Rn exhalation rate and indoor 222Rn/220Rn levels in higher Himalayan terrain
    Sajwan, Rohit Singh
    Joshi, Veena
    Kumar, Naresh
    Ahamad, Taufiq
    Dutt, Sanjay
    Lavanya, Bevinathalapura Shankarappa Kempalingappa
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (11-12) : 1018 - 1026
  • [9] Studies on the electrical characteristics of thoron (220Rn) progeny
    Maniyan, CG
    Louiz, J
    Pillai, PMB
    Khan, AH
    RADIATION PROTECTION DOSIMETRY, 2003, 104 (01) : 55 - 60
  • [10] A simple and versatile 222Rn/220Rn exposure chamber
    Yu, KN
    Koo, VSY
    Guan, ZJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 481 (1-3): : 749 - 755