Construction of glucose biosensor based on sorption of glucose oxidase onto multilayers of polyelectrolyte/nanoparticles

被引:0
作者
Suxia Zhang
Weiwei Yang
Yaming Niu
Yancai Li
Ming Zhang
Changqing Sun
机构
[1] Jilin University,College of Chemistry
来源
Analytical and Bioanalytical Chemistry | 2006年 / 384卷
关键词
Glucose oxidase; Gold nanoparticles; Electrostatic self-assembly; Biosensors; Polyelectrolyte multilayers;
D O I
暂无
中图分类号
学科分类号
摘要
A new approach to constructing an enzyme-containing film on the surface of a gold electrode for use as a biosensor is described. A basic multilayer film (BMF) of (PDDA/GNPs)n/PDDA was first constructed on the gold electrode by electrostatic layer-by-layer self-assembly of poly(diallyldimethylammonium chloride) (PDDA) and gold nanoparticles (GNPs). Glucose oxidase (GOx) was then sorbed into this BMF by dipping the BMF-modified electrode into a GOx solution. The assembly of the BMF was monitored and tested via UV-vis spectroscopy and cyclic voltammetry (CV). The ferrocenemethanol-mediated cyclic voltammograms obtained from the gold electrode modified with the (PDDA/GNPs)n/PDDA/GOx indicated that the assembled GOx remained electrocatalytically active for the oxidation of glucose. Analysis of the voltammetric signals showed that the surface coverage of active enzyme was a linear function of the number of PDDA/GNPs bilayers. This result confirmed the penetration of GOx into the BMF and suggests that the BMF-based enzyme film forms in a uniform manner. Electrochemical impedance measurements revealed that the biosensor had a lower electron transfer resistance (Ret) than that of a sensor prepared by layer-by-layer assembly of PDDA and GOx, due to the presence of gold nanoparticles. The sensitivity of the biosensor for the determination of glucose, which could be controlled by adjusting the number of PDDA/GNPs bilayers, was investigated.
引用
收藏
页码:736 / 741
页数:5
相关论文
共 50 条
[21]   Glucose biosensor based on glucose oxidase and gold nanoparticles of different sizes covered by polypyrrole layer [J].
German, Natalija ;
Ramanavicius, Arunas ;
Voronovic, Jaroslav ;
Ramanaviciene, Almira .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2012, 413 :224-230
[22]   Covalent attachment of glucose oxidase to an Au electrode modified with gold nanoparticles for use as glucose biosensor [J].
Zhang, SX ;
Wang, N ;
Yu, HJ ;
Niu, YM ;
Sun, CQ .
BIOELECTROCHEMISTRY, 2005, 67 (01) :15-22
[23]   Amperometric glucose biosensor based on silver nanowires and glucose oxidase [J].
Wang, Lisha ;
Gao, Xia ;
Jin, Lingyan ;
Wu, Qi ;
Chen, Zhichun ;
Lin, Xianfu .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 :9-14
[24]   Amperometric glucose biosensor based on the deposition of copper and glucose oxidase onto glassy carbon transducer [J].
Rodriguez, MC ;
Rivas, GA .
ANALYTICAL LETTERS, 2000, 33 (12) :2373-2389
[25]   Voltammetric glucose biosensor based on glucose oxidase encapsulation in a chitosan-kappa-carrageenan polyelectrolyte complex [J].
Rassas, Ilhem ;
Braiek, Mohamed ;
Bonhomme, Anne ;
Bessueille, Francois ;
Rafin, Guy ;
Majdoub, Hatem ;
Jaffrezic-Renault, Nicole .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 95 :152-159
[26]   Glucose biosensor based on glucose oxidase immobilized at gold nanoparticles decorated graphene-carbon nanotubes [J].
Devasenathipathy, Rajkumar ;
Mani, Veerappan ;
Chen, Shen-Ming ;
Huang, Sheng-Tung ;
Huang, Tsung-Tao ;
Lin, Chun-Mao ;
Hwa, Kuo-Yuan ;
Chen, Ting-Yo ;
Chen, Bo-Jun .
ENZYME AND MICROBIAL TECHNOLOGY, 2015, 78 :40-45
[27]   Construction of an Amperometric Glucose Biosensor by Immobilization of Glucose Oxidase on Nanocomposite at the Surface of FTO Electrode [J].
Marand, Zahra Rezay ;
Shahtahmassebi, Nasser ;
Housaindokht, Mohammad Reza ;
Rounaghi, Golam Hossien ;
Razavipanah, Iman .
ELECTROANALYSIS, 2014, 26 (04) :840-848
[28]   An enzymatic glucose biosensor based on the codeposition of rhodium, iridium, and glucose oxidase onto a glassy carbon transducer [J].
Rodríguez, MC ;
Rivas, GA .
ANALYTICAL LETTERS, 2001, 34 (11) :1829-1840
[29]   Glucose biosensor based on the highly efficient immobilization of glucose oxidase on layer-by-layer films of silsesquioxane polyelectrolyte [J].
de Jesus, Cliciane Guadalupe ;
Lima, Dhesmon ;
dos Santos, Vagner ;
Wohnrath, Karen ;
Pessoa, Christiana Andrade .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 :44-51
[30]   Layer by layer assembly of glucose oxidase and thiourea onto glassy carbon electrode: Fabrication of glucose biosensor [J].
Salimi, Abdollah ;
Noorbakhsh, Abdollah .
ELECTROCHIMICA ACTA, 2011, 56 (17) :6097-6105