Investigation of membrane fouling at the microscale using isopore filters

被引:1
作者
Majid Ebrahimi Warkiani
Filicia Wicaksana
Anthony Gordon Fane
Hai-Qing Gong
机构
[1] University of New South Wales,School of Mechanical and Manufacturing Engineering, Australian Center for NanoMedicine
[2] Singapore Membrane Technology Centre (SMTC),School of Civil and Environmental Engineering
[3] Nanyang Technological University,School of Mechanical and Aerospace Engineering
[4] Nanyang Technological University,Department of Chemical and Materials Engineering
[5] University of Auckland,undefined
来源
Microfluidics and Nanofluidics | 2015年 / 19卷
关键词
Isopore membrane; Filtration; Fouling; Microfluidics; MEMS;
D O I
暂无
中图分类号
学科分类号
摘要
Investigations of membrane fouling at the pore-scale have long been of limited interest due to microstructural defects of the commercial membranes that prevent any quantitative analysis of the experimental results. In this paper, we employed novel microengineered membranes with regular pore size to investigate the effect of the membrane pore geometry on the fouling mechanisms during filtration of micron-sized particles. For particles larger than the membrane pore size, the fouling mechanism was pore blockage followed by the cake filtration, while pore narrowing was the dominant mechanism when particles were smaller than the membrane pore size. Filtration with the slotted pore membrane offers some interesting advantages comparing to the filtration with circular pores. The rate of flux decline was slower for the membrane with slotted pores compared with the membrane with circular pores since the initial particle deposition only covered a small fraction of the pores. It was also found that the flow resistance of the slotted pore membrane is much lower than the circular one because a slotted pore has a smaller perimeter than several circular pores with the same total surface area. We can conclude that by proper selection of membrane pore geometry, flux decline can be hindered while maintaining a high selectivity during microfiltration. These findings can be useful also for researchers who are using microfluidic platforms with integrated isopore filters for various applications such as stem cell enrichment, cancer cell isolation, blood fractionation and pathogen removal.
引用
收藏
页码:307 / 315
页数:8
相关论文
共 153 条
  • [1] Bacchin P(1995)Model for colloidal fouling of membranes AIChE J 41 368-376
  • [2] Aimar P(2011)Colloidal surface interactions and membrane fouling: investigations at pore scale Adv Colloid Interface Sci 164 2-11
  • [3] Sanchez V(2007)Transmission and fractionation of micro-sized particle suspensions J Membr Sci 290 230-240
  • [4] Bacchin P(2002)Particulate fouling of surface microfilters with slotted and circular pore geometry J Membr Sci 196 27-37
  • [5] Marty A(2006)Effects of membrane pore geometry on fouling behavior during yeast cell microfiltration J Membr Sci 285 334-342
  • [6] Duru P(2010)Polymeric micro-filter manufactured by a dissolving mold technique J Micromech Microeng 20 075005-56
  • [7] Meireles M(2013)Filter characteristics influencing circulating tumor cell enrichment from whole blood PLoS ONE 8 e61770-866
  • [8] Aimar P(2002)Sensitive fluorescent detection of protein on nylon membranes J Biochem Biophys Methods 51 47-136
  • [9] Brans G(2006)A three mechanism model to describe fouling of microfiltration membranes J Membr Sci 280 856-236
  • [10] van Dinther A(1987)A review of fouling and fouling control in ultrafiltration Desalination 62 117-4T