Determination of cocaine and metabolites in hair by column-switching LC-MS-MS analysis

被引:0
作者
Marcela Nogueira Rabelo Alves
Gabriele Zanchetti
Alberto Piccinotti
Silvia Tameni
Bruno Spinosa De Martinis
Aldo Polettini
机构
[1] Universidade de São Paulo,Faculdade de Ciências Farmacêuticas de Ribeirão Preto
[2] Synlab Italia Srl,Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto
[3] Universidade de São Paulo,Department of Public Health and Community Medicine
[4] University of Verona,undefined
来源
Analytical and Bioanalytical Chemistry | 2013年 / 405卷
关键词
Column switching; LC-MS-MS; Hair testing; Cocaine and metabolites; Drugs of abuse;
D O I
暂无
中图分类号
学科分类号
摘要
A method for rapid, selective, and robust determination of cocaine (CO) and metabolites in 5-mg hair samples was developed and fully validated using a column-switching liquid chromatography–tandem mass spectrometry system (LC-MS-MS). Hair samples were decontaminated, segmented, incubated overnight in diluted HCl, and centrifuged, and the diluted (1:10 with distilled water) extracts were analyzed in positive ionization mode monitoring two reactions per analyte. Quantifier transitions were: m/z 304.2→182.2 for CO, m/z 290.1→168.1 for benzoylecgonine (BE), and m/z 318.2→196.2 for cocaethylene (CE). The lower limit of quantification (LLOQ) was set at 0.05 ng/mg for CO and CE, and 0.012 ng/mg for BE. Imprecision and inaccuracy at LLOQ were lower than 20 % for all analytes. Linearity ranged between 0.05 and 50.0 ng/mg for CO and CE and 0.012 and 12.50 ng/mg for BE. Selectivity, matrix effect, process efficiency, recovery, carryover, cross talk, and autosampler stability were also evaluated during validation. Eighteen real hair samples and five samples from a commercial proficiency testing program were comparatively examined with the proposed multidimensional chromatography coupled with tandem mass spectrometry procedure and our reference gas chromatography coupled to mass spectrometry (GC-MS) method. Compared with our reference GC-MS method, column-switching technique and the high sensitivity of the tandem mass spectrometry detection system allowed to significantly reduce sample amount (×10) with increased sensitivity (×2) and sample throughput (×4), to simplify sample preparation, and to avoid that interfering compounds and ions impaired the ionization and detection of the analytes and deteriorate the performance of the ion source.
引用
收藏
页码:6299 / 6306
页数:7
相关论文
共 50 条
[21]   DETERMINATION OF RALOXIFENE HYDROCHLORIDE IN HUMAN URINE BY LC-MS-MS [J].
Kumar, Urdigere R. Anil ;
Basavaiah, Kanakapura ;
Tharpa, Kalsang ;
Vinay, Kanakapura B. .
CHEMICAL INDUSTRY & CHEMICAL ENGINEERING QUARTERLY, 2009, 15 (03) :119-123
[22]   LC-MS-MS Method for Determination of Metolazone in Human Plasma [J].
Roy, Shikha M. N. ;
Mangaonkar, Kiran V. ;
Yetal, Santosh M. ;
Joshi, Santosh. S. .
E-JOURNAL OF CHEMISTRY, 2008, 5 (03) :634-640
[23]   An LC-MS-MS method for the determination of cyclizine in human serum [J].
Mohammadi, A ;
Kanfer, I ;
Sewram, V ;
Walker, RB .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2) :148-152
[24]   Development and Validation of a Column-Switching LC–ESI–MS Assay for Determination of Huperzine A in Rat Plasma and Cerebrospinal Fluid [J].
Jianyang Pan ;
Qiao Wang ;
Qing Shao ;
Yiyu Cheng ;
Haibin Qu .
Chromatographia, 2009, 69 :445-451
[25]   Direct determination of non-steroidal anti-inflammatory drugs by column-switching LC-MS [J].
Suenami, Koichi ;
Lim, Lee Wah ;
Takeuchi, Toyohide ;
Sasajima, Yasuhide ;
Sato, Kiyohito ;
Takekoshi, Yuji ;
Kanno, Susumu .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (18) :2725-2732
[26]   Characterization of in vivo plasma metabolites of tepoxalin in horses using LC-MS-MS [J].
Giorgi, Mario ;
Mengozzi, Grazia ;
Raffaelli, Andrea ;
Saba, Alessandro .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (01) :45-53
[27]   LC-MS-MS identification of drug metabolites obtained by metalloporphyrin mediated oxidation [J].
Maurin, AJM ;
Iamamoto, Y ;
Lopes, NP ;
Lindsay-Smith, JR ;
Bonato, PS .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (02) :322-328
[28]   Determination of N-nitrosodiethanolamine in cosmetic products by LC-MS-MS [J].
Schothorst, RC ;
Somers, HHJ .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (03) :681-685
[29]   Sensitive LC-MS-MS method for the determination of tiopronin in human plasma [J].
Jiang, Bo ;
Xu, Yu ;
Xu, Fang ;
Sun, Junjie ;
Li, Na ;
Luo, Yanan ;
Guo, Qingxiang .
BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (06) :655-662
[30]   LC-MS-MS Determination of (S,R)-Penehyclidine in Rat Plasma [J].
Changkun Li ;
Jinglai Li ;
Mengxun Cui ;
Fenghua Fu ;
Bohua Zhong ;
Zhenqing Zhang .
Chromatographia, 2010, 71 :1025-1030