Beating-heart totally endoscopic coronary artery bypass grafting: Report of a case

被引:0
作者
Satoru Nishida
Go Watanabe
Norihiko Ishikawa
Yujiro Kikuchi
Munehisa Takata
Teruaki Ushijima
机构
[1] Tokyo Medical University,Division of Cardiac Surgery
[2] Kanazawa University Graduate School of Medical Science,Department of General and Cardiothoracic Surgery
来源
Surgery Today | 2010年 / 40卷
关键词
Robot; da Vinci; Totally endoscopic coronary artery bypass grafting; Beating heart; Off-pump;
D O I
暂无
中图分类号
学科分类号
摘要
This case report presents beating-heart totally endoscopic coronary artery bypass grafting (TECAB) for single-vessel coronary artery disease. A 72-year-old man with isolated left anterior descending (LAD) coronary artery disease was considered eligible for TECAB. Left internal thoracic artery (LITA) mobilization and subsequent off-pump revascularization applying the LITA to the LAD in a closed chest environment was performed using the da Vinci surgical system (Intuitive Surgical, Mountain View, CA, USA). The LITA was first harvested completely in a totally skeletonized fashion through three incisions 1–2 cm long in the left thoracic wall. The LAD was immobilized with the aid of a heart stabilizer. The LITA was then anastomosed to the LAD with 10 interrupted sutures of a Nitinol self-closing S15 U-clip device (Medtronic, Minneapolis, MN, USA) on the beating heart without the use of cardiopulmonary bypass. The time acquired to perform anastomosis was 20 min, and the total operative time was 5 h 34 min. The postoperative course was uneventful and the patient was discharged 5 days after the operation. Beating-heart TECAB was successfully performed for this patient with single-vessel LAD disease. This approach may be an evolutionary step toward beating-heart multivessel TECAB.
引用
收藏
页码:57 / 59
页数:2
相关论文
共 47 条
  • [1] Loulmet D.(1999)Endoscopic coronary artery bypass grafting with the aid of robotic assisted instruments J Thorac Cardiovasc Surg 118 4-10
  • [2] Carpentier A.(2006)Results of the prospective multicenter trial of robotically assisted totally endoscopic coronary artery bypass grafting Ann Thorac Surg 81 1666-1674
  • [3] d’Attellis N.(1999)Beatingheart endoscopic coronary artery surgery Lancet 354 2131-2132
  • [4] Berrebi A.(2007)Robotically assisted multivessel minimally invasive direct coronary artery bypass grafting with the use of bilateral internal thoracic arteries Circ J 71 1496-1498
  • [5] Cardon C.(2007)Robotic internal thoracic artery harvesting Surg Today 37 944-946
  • [6] Ponzio O.(2005)Early outcome of a randomized comparison of off-pump and on-pump multiple arterial coronary revascularization Circulation 112 I338-I343
  • [7] Argenziano M.(2005)Off-pump CABG with synchronized arterial flow ensuring system Ann Thorac Surg 80 1893-1897
  • [8] Katz M.(2001)Technique of closed chest coronary artery surgery on the beating heart Eur J Cardiothorac Surg 20 765-769
  • [9] Bonatti J.(undefined)undefined undefined undefined undefined-undefined
  • [10] Srivastava S.(undefined)undefined undefined undefined undefined-undefined