Clinical review of attenuation-corrected cardiac SPECT

被引:0
|
作者
James R. Corbett
Edward P. Ficaro
机构
[1] The University of Michigan Centersl,Department of Internal Medicine, Divisions of Nuclear Medicine and Cardiology
[2] The University of Michigan Hospitals B1G412/ 0028,undefined
来源
Journal of Nuclear Cardiology | 1999年 / 6卷
关键词
Single Photon Emission Compute Tomographic; Myocardial Perfusion Imaging; Attenuation Correction; Nuclear Cardiology; Single Photon Emission Compute Tomographic Imaging;
D O I
暂无
中图分类号
学科分类号
摘要
Rather than the introduction of a heralded technologic advancement in cardiac SPECT imaging challenging the accuracy of PET perfusion imaging, the commercial introduction of attenuation correction, has been met with at least as many negative as positive reports. Some studies have reported significant improvements in specificity or specificity and sensitivity, especially for high-risk patterns of coronary artery disease; others have reported no improvement or a decrease in accuracy resulting from the introduction of troublesome artifacts. Although this review has attempted to emphasize the positive aspects of attenuation-corrected cardiac SPECT perfusion imaging and the potential for improved patient care it may provide, several negative reports continue to appear.68,69,108,109 Still there has been sufficient positive data reported to suggest that with fully developed, accurate, and robust correction methods, significant gains in SPECT assessments, of the presence and extent of CHD, patient risk, and myocardial viability can be anticipated. Ultimately attenuation correction for cardiac SPECT should have a positive impact on the management of patients with coronary artery disease with important savings in lives and health care dollars.
引用
收藏
页码:54 / 68
页数:14
相关论文
共 50 条
  • [1] Comparative Accuracy of CT Attenuation-Corrected and Non-Attenuation-Corrected SPECT Myocardial Perfusion Imaging
    Sharma, Punit
    Patel, Chetan D.
    Karunanithi, Sellam
    Maharjan, Sagar
    Malhotra, Arun
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (04) : 332 - 338
  • [2] Clinical implication of down-scatter in attenuation-corrected myocardial SPECT
    Almquist, H
    Arheden, H
    Arvidsson, AH
    Pahlm, O
    Palmer, J
    JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (04) : 406 - 411
  • [3] Clinical implication of down-scatter in attenuation-corrected myocardial SPECT
    Helén Almquist
    Håkan Arheden
    Ann-Helen Arvidsson
    Olle Pahlm
    John Palmer
    Journal of Nuclear Cardiology, 1999, 6 : 406 - 411
  • [4] Effects of misalignment between transmission and emission scans on attenuation-corrected cardiac SPECT
    Matsunari, I
    Böning, G
    Ziegler, SI
    Kosa, I
    Nekolla, SG
    Ficaro, EP
    Schwaiger, M
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (03) : 411 - 416
  • [5] Cause of apical thinning on attenuation-corrected myocardial perfusion SPECT
    Okuda, Koichi
    Nakajima, Kenichi
    Matsuo, Shinro
    Wakabayashi, Hiroshi
    Taki, Junichi
    Kinuya, Seigo
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (11) : 1033 - 1039
  • [6] Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    Sibyll Goetze
    Richard L. Wahl
    Journal of Nuclear Cardiology, 2007, 14
  • [8] Effects of attenuation map accuracy on attenuation-corrected micro-SPECT images
    Chao Wu
    Hugo A Gratama van Andel
    Peter Laverman
    Otto C Boerman
    Freek J Beekman
    EJNMMI Research, 3
  • [9] Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    Goetze, Sibyll
    Wahl, Richard L.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (02) : 200 - 206
  • [10] Effects of attenuation map accuracy on attenuation-corrected micro-SPECT images
    Wu, Chao
    van Andel, Hugo A. Gratama
    Laverman, Peter
    Boerman, Otto C.
    Beekman, Freek J.
    EJNMMI RESEARCH, 2013, 3 : 1 - 11