Passive dosimeters for nitrogen dioxide in personal/indoor air sampling: A review

被引:0
作者
Chang Ho Yu
Maria T Morandi
Clifford P Weisel
机构
[1] Environmental and Occupational Health Sciences Institute,Exposure Science Division
[2] School of Public Health,undefined
[3] University of Texas HCS,undefined
来源
Journal of Exposure Science & Environmental Epidemiology | 2008年 / 18卷
关键词
nitrogen dioxide; passive sampler; diffusive sampler; personal exposure; indoor sampling;
D O I
暂无
中图分类号
学科分类号
摘要
Accurate measurement of nitrogen dioxide concentrations in both outdoor and indoor environments, including personal exposures, is a fundamental step for linking atmospheric nitrogen dioxide levels to potential health and ecological effects. The measurement has been conducted generally in two ways: active (pumped) sampling and passive (diffusive) sampling. Diffusion samplers, initially developed and used for workplace air monitoring, have been found to be useful and cost-effective alternatives to conventional pumped samplers for monitoring ambient, indoor and personal exposures at the lower concentrations found in environmental settings. Since the 1970s, passive samplers have been deployed for ambient air monitoring in urban and rural sites, and to determine personal and indoor exposure to NO2. This article reviews the development of NO2 passive samplers, the sampling characteristics of passive samplers currently available, and their application in ambient and indoor air monitoring and personal exposure studies. The limitations and advantages of the various passive sampler geometries (i.e., tube, badge, and radial type) are also discussed. This review provides researchers and risk assessors with practical information about NO2 passive samplers, especially useful when designing field sampling strategies for exposure and indoor/outdoor air sampling.
引用
收藏
页码:441 / 451
页数:10
相关论文
共 342 条
[1]  
Algar OG(2004)Concentrations and determinations of NO Indoor Air 14 298-304
[2]  
Pichini S(2004) in homes of Ashford, UK and Barcelona and Menorca, Spain Sci Total Environ 323 99-105
[3]  
Basagana X(1994)Indoor and outdoor concentrations of RSP, NO Arch Environ Health 49 17-24
[4]  
Puig C(2001) and selected volatile organic compounds at 32 shoe stalls located near busy roadways in Seoul, Korea Chromatographia 54 653-657
[5]  
Vall O(2000)Personal NO J Environ Monit 2 1-9
[6]  
Torrent M(2002) exposure monitoring shows high exposure among ice-skating schoolchildren J Limnol 61 69-76
[7]  
Harris J(2001)The internal consistency of the ‘Analyst’ diffusive sampler – a long-term field study Atmos Environ 35 289-296
[8]  
Sunyer J(1994)Monitoring the ambient environment with diffusive samplers: theory and practical considerations Atmos Environ 28 477-486
[9]  
Cullinan P(2000)Ozone and nitrogen dioxide measurements in the framework of National Integrated Programme for the Control of Forest Ecosystem (CONECOFOR) Build Environ 35 545-553
[10]  
Bae H(1996)Validation of nitrogen dioxide diffusion tube methodology in the UK Am Ind Hyg Assoc J 57 897-904