A Multi-loading, Climate-Controlled, Stationary ROI Device for In-Situ X-ray CT Hygro-Thermo-Mechanical Testing

被引:0
作者
N.H. Vonk
E.C.A. Dekkers
M.P.F.H.L. van Maris
J.P.M. Hoefnagels
机构
[1] Eindhoven University of Technology,Department of Mechanical Engineering
[2] Eindhoven University of Technology,Equipment and Prototyping Centre
来源
Experimental Mechanics | 2019年 / 59卷
关键词
mechanical testing; X-ray computed tomography; Climate control; Multi Loading; Stationary ROI; Micro-mechanics;
D O I
暂无
中图分类号
学科分类号
摘要
In-situ CT mechanical testing yields a full 3D description of a sample material’s behaviour under specific loads. In the literature various devices are proposed which enable in-situ CT hygro-, thermo- or mechanical testing, each with its own merits and limitations. However none of them is able to perform advanced hygro-thermo-mechanical tests on specimens subjected to multiple loading modes, while accurately controlling and measuring the force, displacement, temperature and relative humidity in real time. Therefore, this work proposes an in-situ CT device which allows such multi-faceted experiments. Improvements to the current state-of-the-art devices include: (1) a compact, lightweight and rotationally symmetric design that enables high-resolution CT scans by minimization of wobble during scanning, in practically all lab-scale CT scanners; (2) a stationary region of interest by loading the sample from both sides, which enables high resolution CT characterization of materials exhibiting a large fracture strain; and (3) improved testing modularity by exchanging clamping methods to allow samples of various sizes (e.g., circular or rectangular) to be inserted in a variety of ways, thereby facilitating complex experiments such as three- or four-point bending tests. Validation experiments demonstrate that stringent requirements on CT resolution, loading and displacement accuracy and climate control are met. Furthermore, the in-situ testing capabilities of the device were validated by CT characterization of the creasing and folding process of multi-layer cardboard under varying (controlled) levels of relative humidity and temperature.
引用
收藏
页码:295 / 308
页数:13
相关论文
共 103 条
[1]  
Sket F(2016)X-ray computed tomography analysis of damage evolution in open hole carbon fiber-reinforced laminates subjected to in-plane shear Combust Sci Technol 133 40-50
[2]  
Enfedaque A(2009)Computed tomography-based modeling of structured polymers J Cell Plast 45 157-179
[3]  
López CD(2016)Observations by in-situ x-ray synchrotron computed tomography of the microstructural evolution of semi-crystalline polyamide 11 during deformation Polym Test. 56 245-260
[4]  
González C(2010)In situ experiments with x-ray tomography: an attractive tool for experimental mechanics Exp Mech 50 289-305
[5]  
Molina-Aldareguía J(2016)Nanox: a miniature mechanical stress rig designed for near-field X-ray diffraction imaging techniques J Synchrotron Radiat 23 1474-1483
[6]  
Llorca J(2003)A 1300 k furnace for in-situ x-ray microtomography J Appl Crystallogr 36 366-367
[7]  
Wismans J(2017)In-situ tensile tests under sem and x-ray computed micro-tomography aimed at studying a self-healing matrix composite submitted to different thermomechanical cycles J Eur Ceram Soc 37 3471-3474
[8]  
Dommelen JV(2017)Hydration forces between aligned DNA helices undergoing b to a conformational change: In-situ x-ray fiber diffraction studies in a humidity and temperature controlled environment J Struct Biol 200 283-292
[9]  
Govaert L(2017)X-ray tomographic imaging of tensile deformation modes of electrospun biodegradable polyester fibers Front Mater 4 43-208
[10]  
Meijer H(2016)In-situ x-ray study of the deformation mechanisms of non-woven polypropylene Int J Solids Struct 97–98 200-3401