1.0 T open-configuration magnetic resonance-guided microwave ablation of pig livers in real time

被引:0
作者
Jun Dong
Liang Zhang
Wang Li
Siyue Mao
Yiqi Wang
Deling Wang
Lujun Shen
Annan Dong
Peihong Wu
机构
[1] Sun Yat-Sen University Cancer Center,Department of Medical Imaging & Image Guided Therapy
[2] State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine,undefined
来源
Scientific Reports | / 5卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The current fastest frame rate of each single image slice in MR-guided ablation is 1.3 seconds, which means delayed imaging for human at an average reaction time: 0.33 seconds. The delayed imaging greatly limits the accuracy of puncture and ablation and results in puncture injury or incomplete ablation. To overcome delayed imaging and obtain real-time imaging, the study was performed using a 1.0-T whole-body open configuration MR scanner in the livers of 10 Wuzhishan pigs. A respiratory-triggered liver matrix array was explored to guide and monitor microwave ablation in real-time. We successfully performed the entire ablation procedure under MR real-time guidance at 0.202 s, the fastest frame rate for each single image slice. The puncture time ranged from 23 min to 3 min. For the pigs, the mean puncture time was shorted to 4.75 minutes and the mean ablation time was 11.25 minutes at power 70 W. The mean length and widths were 4.62 ± 0.24 cm and 2.64 ± 0.13 cm, respectively. No complications or ablation related deaths during or after ablation were observed. In the current study, MR is able to guide microwave ablation like ultrasound in real-time guidance showing great potential for the treatment of liver tumors.
引用
收藏
相关论文
共 21 条
  • [1] Clasen S(2008)Magnetic resonance guidance for radiofrequency ablation of liver tumors JMRI 27 421-433
  • [2] Pereira PL(2002)MR‐guided microwave thermocoagulation therapy of liver tumors: Initial clinical experiences using a 0.5 T open MR system JMRI 16 576-583
  • [3] Morikawa S(2001)Clinical experiences with MR-guided microwave ablation for liver tumors ISMRM. Vol. 9 2204-373
  • [4] Kurumi Y(2004)Feasibility of respiratory triggering for MR-guided microwave ablation of liver tumors under general anesthesia CIR 27 370-31
  • [5] Tani T(2005)Open-configuration MR-guided microwave thermocoagulation therapy for metastatic liver tumors from breast cancer BC 12 26-428
  • [6] Naka S(2013)Magnetic resonance-guided freehand radio-frequency ablation of malignant liver lesions: A new simplified and time-efficient approach using an interactive open magnetic resonance scan platform and hepatocyte-specific contrast agent IR 48 422-332
  • [7] Morikawa S(2010)Pilot evaluation of a novel clinical test of reaction time in national collegiate athletic association division I football players JAT 45 327-1502
  • [8] Inubushi T(2013)Dynamic contrast-enhanced magnetic resonance imaging for characterising nasopharyngeal carcinoma: comparison of semiquantitative and quantitative parameters and correlation with tumour stage ER 23 1495-393
  • [9] Morikawa S(2011)An integrated perspective on the relation between response speed and intelligence Cognition 119 381-130
  • [10] Abe H(2011)A comparison of microwave ablation and bipolar radiofrequency ablation both with an internally cooled antenna: results in EJR 79 124-1990