Development of new rat monoclonal antibodies with different selectivities and sensitivities for 2,4,6-trinitrotoluene (TNT) and other nitroaromatic compounds

被引:0
作者
Petra M. Krämer
Elisabeth Kremmer
Cristina M. Weber
Ioan M. Ciumasu
Stephan Forster
Antonius A. Kettrup
机构
[1] Institute of Ecological Chemistry,GSF—National Research Centre for Environment and Health
[2] Technische Universität München,Wissenschaftszentrum Weihenstephan, Lehrstuhl für Ökologische Chemie und Umweltanalytik
[3] Institute of Molecular Immunology,GSF—National Research Centre for Environment and Health
来源
Analytical and Bioanalytical Chemistry | 2005年 / 382卷
关键词
TNT; 2-Amino-4,6-dinitrotoluene; 4-Amino-2,6-dinitrotoluene; Nitroaromatic compounds; Immunoassay; Monoclonal antibodies; Water; Pattern recognition;
D O I
暂无
中图分类号
学科分类号
摘要
Five new rat monoclonal antibodies (mAbs) for 2,4,6-trinitrotoluene (TNT) and other nitroaromatic compounds, including, especially, the metabolite 2-amino-4,6-dinitrotoluene (2-ADNT), are described. Five heterogeneous, competitive enzyme-linked immunosorbent assays (ELISAs) were developed. Assay 1 uses mAb DNT4 3F6 as recognition element and gives a standard curve for TNT in 40 mmol L−1 phosphate buffered saline (PBS) with a test midpoint (IC50) of 0.26±0.08 μg L−1 (n=20). Assay 2 (mAb DNT4 4G4) has an IC50 of 0.35±0.07 μg L−1 (n=18), assay 3 (mAb DNT4 1A3) has an IC50 of 0.73±0.14 μg L−1 (n=15), and assay 4 (mAb DNT4 1A7) has an IC50 of 2.32±0.70 μg L−1 (n=15). Assay 5 (mAb DNT2 4B4) is very selective for 2-ADNT and has an IC50 of 8.5±1.7 μg L−1 (n=15) in PBS. These antibodies for nitroaromatic compounds differ not only in their sensitivity but also in their selectivity. Major cross-reactants are 1,3,5-trinitrobenzene, 2-ADNT, 4-amino-2,6-dinitrotoluene (4-ADNT), 2,4-dinitroaniline, 3,5-dinitroaniline, and 2,6-dinitroaniline. Although assay 5 is not highly sensitive, the mAb DNT2 4B4 in this assay is highly selective for 2-ADNT. Of all the compounds tested, only 2,4-dinitroaniline and 3,5-dinitroaniline had relevant cross reactivities, 18% and about 26%, respectively. Two ELISAs, using mAbs DNT4 3F6 and DNT2 4B4, were used to analyze different concentrations of TNT and 2-ADNT, respectively, in three different surface water matrices (river and lake water). Both assays were affected by the matrix, but usually performed well (recovery within the range 70–120%). In addition, these ELISAs were used to analyze mixtures of TNT, 2-ADNT, and 4-ADNT, at three different concentrations, in the same water matrices. A different recognition pattern was clearly visible with both assays and depended on the cross reactivities of the corresponding mAb.
引用
收藏
页码:1919 / 1933
页数:14
相关论文
共 143 条
[1]  
Kaplan DL(1982)undefined Environ Sci Technol 16 566-undefined
[2]  
Kaplan AM(2003)undefined Occup Environ Med 60 483-undefined
[3]  
Letzel S(1998)undefined Environ Sci Technol 32 1676-undefined
[4]  
Göen Th(2004)undefined J Environ Manag 70 291-undefined
[5]  
Bader M(1997)undefined Fresenius J Anal Chem 357 333-undefined
[6]  
Angerer J(1999)undefined J Chromatogr A 849 381-undefined
[7]  
Kraus T(1998)undefined Environ Sci Technol 32 1354-undefined
[8]  
Bruns-Nagel D(1998)undefined J Chromatogr B 710 91-undefined
[9]  
Drzyzga O(2000)undefined Global Nest: Int J 2 227-undefined
[10]  
Steinbach K(1992)undefined Talanta 39 419-undefined