CO2 laser as auxiliary in the debonding of ceramic brackets

被引:0
作者
Rodrigo Teixeira Macri
Fabrício Augusto de Lima
Luciano Bachmann
Rodrigo Galo
Fábio Lourenço Romano
Maria Cristina Borsatto
Mírian Aiko Nakane Matsumoto
机构
[1] University of São Paulo,Department of Pediatric Dentistry, School of Dentistry of Ribeirão Preto
[2] University of São Paulo,Department Vibrational Spectroscopy, Physics Department
[3] University of São Paulo,Department of Physics and Mathematics
[4] University of São Paulo - USP,Departament of Pediatric Dentistry, School of Dentistry of Ribeirão Preto
来源
Lasers in Medical Science | 2015年 / 30卷
关键词
Carbon dioxide; Dental debonding; Lasers; Orthodontic brackets; Shear strength;
D O I
暂无
中图分类号
学科分类号
摘要
This study evaluated the temperature in the bonding composite and in the pulp chamber, the shear bond strength after the irradiation of CO2 lasers, and the Adhesive Remnant Index (ARI) after debonding of ceramic bracket. A hundred and five premolars were used: 30 to evaluate the temperature and 75 to test the resistance to shear and the ARI. To assess the temperature, different irradiation times (3 and 5 s), pulse duration (0.001 and 0.003 s), and output power (5, 8, and 10 W) were tested (total of 12 groups). During all the irradiation, specimens were immersed in thermal bath water at 37 °C. In the test and ARI evaluation, premolars were divided into five groups (n = 15) and were submitted to the following regimens of CO2 laser irradiation: I (5 W, pulse duration = 0.01 s, application time = 3 s), II (5 W, 0.03 s, 3 s), III (8 W, 0.01 s, 3 s), and IV (1 0 W, 0.01 s, 3 s). Group C (control) was not subjected to irradiation. ARI was measured after debonding of the bracket. Following irradiation of the lasers, the pulpal temperature was not higher than 5.5 °C in four of the study groups. Results were submitted to the ANOVA and Duncan’s test. CO2 laser irradiation regimen IV was one in which the strength of debonding is 7.33 MPa. Therefore, CO2 laser may aid removal of ceramic brackets; it decreased the bond strength without increasing the excessive temperature excessively.
引用
收藏
页码:1835 / 1841
页数:6
相关论文
共 76 条
[1]  
Karamouzous A(1997)Physical proprieties of ceramic brackets Am J Orthod Dentofac Orthop 112 35-40
[2]  
Athnasiou E(2007)Physical properties and clinical characteristics of ceramic brackets: a comprehensive review Trends Biomater Artif Organs 20 201-209
[3]  
Papadopoulos P(1988)Shear bond strength of metal brackets compared with a new ceramic bracket Am J Orthod Dentofac Orthop 94 201-206
[4]  
Jena AK(2003)Laser debonding of ceramic brackets: a comprehensive review Am J Orthod Dentofac Orthop 123 79-83
[5]  
Duggal R(2008)Enamel cracks and ceramic bracket failure during debonding in vitro Angle Orthod 8 1078-1083
[6]  
Mehrotra AK(2010)Effects of CO2 laser debonding of a ceramic bracket on the mechanical properties of enamel Angle Orthod 80 1029-1035
[7]  
Odegaard J(2000)The force levels required to mechanically debond ceramic brackets: an in vitro comparative study Eur J Orthod 22 327-334
[8]  
Segner D(1995)Comparison of different bonding materials for laser debonding Am J Orthod Dentofac Orthop 108 267-273
[9]  
Azzeh E(1996)Ceramic bracket debonding with the carbon dioxide laser Am J Orthod Dentofac Orthop 110 388-393
[10]  
Feldon PJ(1997)In vitro comparison of debonding force and intrapulpal temperature changes during ceramic orthodontic bracket removal using a carbon dioxide laser Am J Orthod Dentofac Orthop 111 203-210